PowerFlex Manager 4.x Unable to change node OS password from PowerFlex Manager

Summary: Unable to change the node operating system password using PowerFlex Manager with error VXFM00685. After changing a password in the PowerFlex Manager UI for node, errors show failure.

This article applies to This article does not apply to This article is not tied to any specific product. Not all product versions are identified in this article.

Symptoms

Errors below are shown in the PowerFlex Manager UI:

  • Invalid credentials request, old credentials, and new credentials are the same or unchanged. (VXFM00685)
  • Could not be connected through SSH due to an unexpected SSH connection error. (VXFM00445)

Deployment job logs show error:

  • Error discovering, jobId=<job-ID>
  • Discovery by IP range failed for device: serviceTag *** cannot be discovered because Puppet module scaleio was not available or failed to return the device information.

 

Cause

Changing the password in the existing OS Admin credential does not update the node root password on the node. PowerFlex manager still needs this credential to match the existing root password in order to connect to the node to run the password change command.

 

Resolution

Follow the PowerFlex Administration guide Updating passwords for nodes section to modify the password for the supported method.

 

Additional Information

Affected Product: PowerFlex Manager 4.x

 

Affected Products

PowerFlex Appliance, PowerFlex appliance R650, PowerFlex appliance R6525, PowerFlex appliance R660, PowerFlex appliance R6625, Powerflex appliance R750, PowerFlex appliance R760, PowerFlex appliance R640, PowerFlex appliance R740XD , PowerFlex appliance R7525 ...

Products

PowerFlex rack, PowerFlex custom node, PowerFlex appliance R7625, PowerFlex custom node, PowerFlex custom node R650, PowerFlex custom node R6525, PowerFlex custom node R660, PowerFlex custom node R6625, PowerFlex custom node R750 , PowerFlex custom node R760, PowerFlex custom node R7625, PowerFlex rack RCM Software, PowerFlex Software, PowerFlex appliance R840 ...