Data Domain: Disk Unknown

Yhteenveto: This article explains why a disk may appear as "Unknown" in a Data Domain system and provides steps to identify and resolve the issue.

Tämä artikkeli koskee tuotetta Tämä artikkeli ei koske tuotetta Tämä artikkeli ei liity tiettyyn tuotteeseen. Tässä artikkelissa ei yksilöidä kaikkia tuoteversioita.

Oireet

A disk displays the state "Unknown" in the DD-CLI, DDSM, or DDMC.

The issue affects one of the following scenarios:

  • A single disk in the controller (head unit) or attached storage
  • All disks in a newly added enclosure
  • A disk recently replaced after failure

Syy

A disk may report as "Unknown" for one of the following reasons:

  • The system has not yet recognized a newly installed disk.
  • A disk is unreliable or failed and reports an unknown state.
  • A newly added enclosure has not been integrated into the RAID configuration.
  • A replacement disk has not been initialized or transitioned to an active state.

Tarkkuus

Follow the steps below based on the scenario:

  1. Check Your Data Domain Model

    Important: The disk unfail command is not supported on storage pool architecture systems (for example, DD6400). Running this command on these models results in an error.

    • Identify your system model:

      system show modelno
      
    • Use the correct procedure:

      DD6400 (Storage Pool Architecture):

      All Other Data Domain Models (Traditional DD-RAID Architecture):

      • Continue with the steps below (disk rescan, disk unfail).
  2. Verify Disk State

  3. Single Disk Reports "Unknown" (and is NOT a new replacement disk)

    • Check active system alerts (alerts show current) and disk state (disk show state). If the disk is reported as failed, and is in an "Unknown" state, replace it.
    • If the "Unknown" disk is a newly installed (replacement) disk, see Step 5.
  4. All Disks in a New Enclosure Report "Unknown"

    • This is expected behavior for a newly added shelf.
      • Follow the relevant Shelf Hardware Guide to get the "Unknown" disks added to storage capacity.
        • Overview of the required steps to add a shelf:
          • Apply licensing
          • Add storage to the correct tier (active or cloud)
          • Expand the filesystem
  5. Single Disk Reports "Unknown" After Replacement

    • Attempt a rescan of drives. From DD-CLI (ssh), Run command # disk rescan
    • Verify status of drive from DD-CLI # disk show state
      • If the disk has become 'In-use' and the alert has not cleared, manually clear the alert using DD-CLI # alerts clear alert-id <alert-id>
      • If the disk remains 'unknown' - run the # disk unfail <encl.disc> command to transition the disk to a spare state.
  6. Need Additional Assistance
    Contact your contracted support provider and raise a service request if the issue remains unresolved.

Lisätietoja

Best Practice: Two-Minute Wait During Disk Swap

  • When physically replacing a disk drive, wait at least 2 minutes after removing the failed disk before inserting the new disk.
  • This allows the controller firmware to properly deregister the old drive, greatly reducing the possibility of a hotplug issue where the new drive is not properly recognized (showing as "unknown").

Recommended sequence:

  1. Remove the failed disk from the slot.
  2. Wait two minutes.
  3. Insert the new replacement disk.

Tuotteet, joihin vaikutus kohdistuu

Data Domain

Tuotteet

Data Domain
Artikkelin ominaisuudet
Artikkelin numero: 000043258
Artikkelin tyyppi: Solution
Viimeksi muutettu: 30 kesäk. 2026
Versio:  6
Etsi vastauksia kysymyksiisi muilta Dell-käyttäjiltä
Tukipalvelut
Tarkista, kuuluuko laitteesi tukipalveluiden piiriin.