地理位置分散的災難重新開機:使用 Dynamic REXX API 發出 SRDF-HC 命令時,GDDR 無法辨識 Nonzero 返回代碼
Yhteenveto: 使用動態 REXX API 發出主機元件命令時,GDDR 無法辨識非零件返回代碼。
Tämä artikkeli koskee tuotetta
Tämä artikkeli ei koske tuotetta
Tämä artikkeli ei liity tiettyyn tuotteeseen.
Tässä artikkelissa ei yksilöidä kaikkia tuoteversioita.
Oireet
如果 SRDF 主機元件命令在 GDDR 指令檔期間失敗,訊息GDDR313I可能會不正確地指出 RC=0 (如下所示),且腳本可能會繼續,就像命令成功一樣。
GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498
Syy
這是軟體問題。
Tarkkuus
解決方案:
- 若為 GDDR 6.0,PTF GD60021可解決此問題。可從 Dell 線上支援下載。
- 若為 GDDR 5.3,PTF GD53104可解決此問題。可從 Dell 線上支援下載。
Lisätietoja
PTF 主機殼蓋注意事項:
- GDDR 6.0L
++PTF(GD60021) REWORK(2023160) . ++VER(Z038) FMID(GDDR600) PRE( GD60014 ) /* *------------------------------------------------------------- * PROBLEM DESCRIPTION(S): * ------------------------------------------------------------ * * PROBLEM FIXED: GDDR-3601 * USERS AFFECTED: GDDR VMAX/PowerMax users * PROBLEM DESCRIPTION: GDDR script may not recognize non-zero * return code from SRDF HC command * * DESCRIPTION DETAIL: * * If an SRDF Host Component command fails during a GDDR * script, message GDDR313I could incorrectly indicate RC=0 * (example below) and the script could proceed as if the * command was successful. * * GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498 * * PROBLEM RESOLUTION: * * If an SRDF Host Component command fails during a GDDR * script, the return code will now be displayed correctly in * the GDDR313I message, and the script will handle the failure * as appropriate. * * In addition, message GDDR313I has been enhanced to avoid any * confusion as to what return code is displayed. Instead of * always indicating 'EMCSRDFR RC=', the message will now * indicate 'EMCSRDFR RC=', 'EMCSRDF_RC=', 'EMCSRDF_CMD_RC=', * or 'IRXEXCOM RC=' so it is clear exactly which return code * is displayed. * * MODULES: GDDRDAP4 * GDDRMTXT * * ------------------------------------------------------------
- GDDR 5.3
++PTF(GD53104) REWORK(2023088) .
++VER(Z038) FMID(GDDR530)
PRE(
GD53096
)
/*
*-------------------------------------------------------------
* PROBLEM DESCRIPTION(S):
* ------------------------------------------------------------
*
* PROBLEM FIXED: GDDR-3602
* USERS AFFECTED: GDDR VMAX/PowerMax users
* PROBLEM DESCRIPTION: GDDR script may not recognize non-zero
* return code from SRDF HC command
*
* DESCRIPTION DETAIL:
*
* If an SRDF Host Component command fails during a GDDR
* script, message GDDR313I could incorrectly indicate RC=0
* (example below) and the script could proceed as if the
* command was successful.
*
* GDDR313I (35) (DYN) EMCSRDFR RC=0 Seconds=0.366498
*
* PROBLEM RESOLUTION:
*
* If an SRDF Host Component command fails during a GDDR
* script, the return code will now be displayed correctly in
* the GDDR313I message, and the script will handle the failure
* as appropriate.
*
* In addition, message GDDR313I has been enhanced to avoid any
* confusion as to which return code is displayed. Instead of
* always indicating 'EMCSRDFR RC=', the message will now
* indicate 'EMCSRDFR RC=', 'EMCSRDF_RC=', 'EMCSRDF_CMD_RC=',
* or 'IRXEXCOM RC=' so it is clear exactly which return code
* is displayed.
*
* MODULES: GDDRDAP4
* GDDRMTXT
*
* ------------------------------------------------------------
* GD53104 29 Mar 2023 14:49:11
* ------------------------------------------------------------
* OPT Summary
* The following OPT was addressed by this PTF:
*
* GDDR-3602
*
*------------------------------------------------------------- Tuotteet, joihin vaikutus kohdistuu