PowerStore: Clusters that have SAS Expansion Enclosures may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5
Résumé: Clusters that have one or more SAS Expansion Enclosures, may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5.
Cet article concerne
Cet article ne concerne pas
Cet article n’est associé à aucun produit spécifique.
Toutes les versions du produit ne sont pas identifiées dans cet article.
Symptômes
The PowerStore nodes may unexpectedly reboot if these conditions are met:
- The cluster is on PowerStoreOS version 3.0.x, 3.2.x, or 3.5.x.
- There are one or more SAS expansion enclosures attached to any of the appliances in the cluster.
Cause
The SAS drivers may time out due to a lock issue on the SAS controller.
This in turn causes a node unexpected reboot.
This in turn causes a node unexpected reboot.
Résolution
The issue is resolved in PowerStoreOS version 3.6 and above.