PowerStore: Pre-Upgrade Health Check (PUHC) detects if CHAP transit connection is properly configured
Riepilogo: Pre-Upgrade Health Check (PUHC) detects if CHAP transit connection is properly configured
Questo articolo si applica a
Questo articolo non si applica a
Questo articolo non è legato a un prodotto specifico.
Non tutte le versioni del prodotto sono identificate in questo articolo.
Sintomi
The PowerStore health check (PUHC) may fail the CHAP transit connection configuration validation, with the following error: "CHAP authentication failure is detected. Please contact your service provider. (off_release_bsc_check_chap_authentication)".
The error code 0xE10050020201 is used for this issue.
Note: This PUHC check was enhanced to avoid failure when Storage Direct backup is configured on the affected cluster.
The error code 0xE10050020201 is used for this issue.
Note: This PUHC check was enhanced to avoid failure when Storage Direct backup is configured on the affected cluster.
Causa
The format of the iSCSI transit connection used by PowerStore was changed in PowerStore 3.x in order to support iBasic. After upgrading from 2.x to 3.x the legacy CHAP transit connection format will cause NDU to fail when SDNAS is used. If CHAP is enabled, the PUHC check will detect the legacy iSCSI transit connection when SDNAS is being used.
To encounter this issue the following 3 conditions would need to be present:
To encounter this issue the following 3 conditions would need to be present:
- CHAP (Single/Mutual) is enabled
- SDNAS is configured
- System was once running V2 and subsequently upgraded to V3
Risoluzione
To resolve this issue, contact technical support for assistance. Reference KB #000214503 for expedited attention and resolution.
Informazioni aggiuntive
The health check is an off-release PUHC check that is contained in the Health Check thin package.
For more information regarding off-release PUHC see KB 000192601 PowerStore: How to Check the Health of the Cluster Before Software Upgrade Using Pre-Upgrade Health Check and System Check.
For more information regarding off-release PUHC see KB 000192601 PowerStore: How to Check the Health of the Cluster Before Software Upgrade Using Pre-Upgrade Health Check and System Check.
Prodotti interessati
PowerStoreProprietà dell'articolo
Numero articolo: 000214503
Tipo di articolo: Solution
Ultima modifica: 14 giu 2025
Versione: 4