Windows Server: Clustered Virtual Machine Missing from Failover Cluster Manager

Riepilogo: A virtual machine (VM) in a Windows Server Hyper-V cluster may not appear as expected in Failover Cluster Manager.

Questo articolo si applica a Questo articolo non si applica a Questo articolo non è legato a un prodotto specifico. Non tutte le versioni del prodotto sono identificate in questo articolo.

Sintomi

At least one clustered VM is not listed in the Roles tab of Failover Cluster Manager. The VM in question appears in Hyper-V Manager on one of the cluster nodes. However, Hyper-V Manager indicates that some of the VM's settings cannot be modified because it is clustered.

Causa

This can occur if the VM's display name has changed since its creation.

Risoluzione

The affected VM may be listed in the Roles tab under a different name. This is more likely on a cluster that hosts many VMs than one that hosts only a few. To determine whether this is the case, follow these steps:

  1. On a cluster node, launch an elevated PowerShell prompt.
  2. Run the command:
Get-ClusterResource
  1. Check the Name column of the output for the affected VM.
  2. If the affected VM is listed in the output, it is present in the cluster.
  3. The name in the OwnerGroup column shows the name by which the VM is listed in Failover Cluster Manager. If necessary, confirm that it is the correct VM by connecting to it.
  4. In Failover Cluster Manager, right-click the VM (using the name shown in step 5) and select Properties.
  5. Correct the VM's display name and click OK. It should now be listed as expected.

Prodotti interessati

Microsoft Windows Server 2016, Microsoft Windows Server 2019, Microsoft Windows Server 2022

Prodotti

PowerEdge FC640, PowerEdge M640, PowerEdge M640 (for PE VRTX), PowerEdge MX5016s, PowerEdge MX740C, PowerEdge MX750c, PowerEdge MX760c, PowerEdge MX840C, PowerEdge R240, PowerEdge R250, PowerEdge R260, PowerEdge R340, PowerEdge R350, PowerEdge R360 , PowerEdge R440, PowerEdge R450, PowerEdge R540, PowerEdge R550, PowerEdge R640, PowerEdge R6415, PowerEdge R650, PowerEdge R650xs, PowerEdge R6515, PowerEdge R6525, PowerEdge R660, PowerEdge R660xs, PowerEdge R6615, PowerEdge R6625, PowerEdge R740, PowerEdge R740XD, PowerEdge R740XD2, PowerEdge R7415, PowerEdge R7425, PowerEdge R750, PowerEdge R750XA, PowerEdge R750xs, PowerEdge R7515, PowerEdge R7525, PowerEdge R760, PowerEdge R760XA, PowerEdge R760xd2, PowerEdge R760xs, PowerEdge R7615, PowerEdge R7625, PowerEdge R840, PowerEdge R860, PowerEdge R940, PowerEdge R940xa, PowerEdge R960, PowerEdge T140, PowerEdge T150, PowerEdge T160, PowerEdge T340, PowerEdge T350, PowerEdge T360, PowerEdge T440, PowerEdge T550, PowerEdge T560, PowerEdge T640 ...
Proprietà dell'articolo
Numero articolo: 000216625
Tipo di articolo: Solution
Ultima modifica: 16 dic 2024
Versione:  5
Trova risposta alle tue domande dagli altri utenti Dell
Support Services
Verifica che il dispositivo sia coperto dai Servizi di supporto.