PowerStore: I/O error observed on NVMe datastore during NDU
Riepilogo: ESXi host running 8.0 U1 using NVMe/FC and NVMe/TCP datastore may experience I/O errors during PowerStore node reboots/failures.
Questo articolo si applica a
Questo articolo non si applica a
Questo articolo non è legato a un prodotto specifico.
Non tutte le versioni del prodotto sono identificate in questo articolo.
Sintomi
Symptoms:
Environment:
- Hosts connected using NVMe/FC or NVMe/TCP may experience I/O errors during node reboots or NDU.
Environment:
- ESXi Host 8.0 U1 is connected to PowerStore volumes/vVols.
- Host is connected using NVMe/FC or NVMe/TCP.
Causa
This is a VMware regression issue introduced in ESXI version 8. 0 U1. In this release, ESXi introduced a Native NVMe stack (aka E2E NVMe stack). Certain error codes that had a retry in previous versions of ESXI no longer have a retry applied. As a result the end applications may experience I/O failures.
Risoluzione
Upgrade ESXI to version 8.0 U1c or later.
Informazioni aggiuntive
VMware KB Article: Rebooting the storage node on the target side may affect VM IOs using the vVOL datastore. (94106)
Prodotti interessati
PowerStoreProprietà dell'articolo
Numero articolo: 000216664
Tipo di articolo: Solution
Ultima modifica: 14 giu 2025
Versione: 4
Trova risposta alle tue domande dagli altri utenti Dell
Support Services
Verifica che il dispositivo sia coperto dai Servizi di supporto.