VxRail: Node Add Failure E3100_VAL_163 With Error 'Management_vmk5'
Riepilogo: Adding a node fails due to incorrect VMK tagging.
Questo articolo si applica a
Questo articolo non si applica a
Questo articolo non è legato a un prodotto specifico.
Non tutte le versioni del prodotto sono identificate in questo articolo.
Sintomi
VxRail Node add failure: E3100_VAL_163 with KeyError: 'Management_vmk5'
short.term.log:
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875452176Z stdout F 2025-05-07T20:35:40.874Z <f8f6ee5639a198a445bd64701281702a> nano-service [ERROR] <140199519385568> validator.py execute() (72): Validator H
ostNetworkMtuValidator raise a Exception 'Management_vmk5'"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.87546302Z stdout F Traceback (most recent call last):"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875465772Z stdout F File ""/home/app/common/validator.py"", line 70, in execute"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875468252Z stdout F raw_result = self.perform(*args, **kwargs)"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875470582Z stdout F ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875473119Z stdout F File ""/home/app/hostnetworkmtuvalidator/host_network_mtu_validator.py"", line 38, in perform"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875475387Z stdout F nodes_net_mtu_info = self._gpl_get_hosts_network_mtu()"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875477555Z stdout F ^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875480603Z stdout F File ""/home/app/hostnetworkmtuvalidator/host_network_mtu_validator.py"", line 50, in _gpl_get_hosts_network_mtu"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875483164Z stdout F nodes_net_mtu_info[f'Management_
{vnic.get(""device"")}
'].append([configured_host.get('name'), vnic.get('device') , vnic.get('mtu')])"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875485447Z stdout F ~~~~~~~~~~~~~~~~~~^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^^"
"2025-05-07 20:35:41,394" microservice.nano-service "2025-05-07T20:35:40.875487995Z stdout F KeyError: 'Management_vmk5'"Causa
This error occurs when a nondefault VMkernel interface (as in, vmk5) is incorrectly tagged with the Management network role. By design, only vmk0 and vmk2 are expected to carry the Management tag. If any other VMkernel interface is assigned with this tag, the VxRail Manager fails to identify the correct management path, resulting in a KeyError during node validation.
Risoluzione
- If any other VMkernel interface (e.g., vmk5) is tagged with Management, remove the tag in the vSphere UI
- Retry the node addition process.
Prodotti interessati
VxRail, VxRail 460 and 470 Nodes, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E460, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N
, VxRail E665, VxRail E665F, VxRail E665N, VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P470, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S470, VxRail S570, VxRail S670, VxRail Software, VxRail V Series Nodes, VxRail V470, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VE-670, VxRail VP-760, VxRail VP-7625, VxRail VP-770, VxRail VS-760
...