Connectrix MDS upgrade returns message "Pre-upgrade check failed "Return code -1."
요약: When performing Connectrix MDS upgrade, the "install all" command returns the message "Pre-upgrade check failed. "Return code -1."
이 문서는 다음에 적용됩니다.
이 문서는 다음에 적용되지 않습니다.
이 문서는 특정 제품과 관련이 없습니다.
모든 제품 버전이 이 문서에 나와 있는 것은 아닙니다.
증상
On attempt to run "install all" command, the switch returns the message "Pre-upgrade check failed. "Return code -1."
No indications of what is wrong, md5sum of the firmware files are good. Enough space on the bootflash: and also on the standby supervisor but still the "install all" command fails with "Return code -1."
No indications of what is wrong, md5sum of the firmware files are good. Enough space on the bootflash: and also on the standby supervisor but still the "install all" command fails with "Return code -1."
원인
The command
runs fine.
The command
(This is the same message as the "install all" command.)
"show incompatibility-all system bootflash:m9700-sf2ek9-xxxx.bin"
runs fine.
The command
"show install all impact kickstart bootflash:m9700-sf2ek9-kickstart-mz.xxxx.bin system bootflash:m9700-sf2ek9-mz.xxxx.bin" fails with "Return code -1."
(This is the same message as the "install all" command.)
해결
Workaround:
- Perform a "system switchover" command to failover to the second supervisor. Wait until the command completes. Use the command "show system redundancy status" to confirm the action completes.
- Perform a second "system switchover" command to go back to the previously active supervisor where the upgrade code currently resides.
- Rerun the "install all" command and upgrade should complete.