DLM: DLMSCR messages for volume not found
Sammendrag: DLMSCR is attempting to scratch tapes which reside only in a customer's legacy virtual tape system, not the DLm.
Denne artikkelen gjelder for
Denne artikkelen gjelder ikke for
Denne artikkelen er ikke knyttet til noe bestemt produkt.
Det er ikke produktversjonene som identifiseres i denne artikkelen.
Symptomer
After a migration from another vendor Virtual Tape System to the DLm using third-party software, the DLMSCR job is running a long time and producing numerous 'volume not found' messages.
DLMSCR VER 4.42 DLMCTRL = C5FF PARM(TYPE=RMM,PREFIX=IB,PREFIXLN=1,DEV=C 2021/02/18 08:45:12 VOLUME BFL111 REQUEST REJECT - VOLUME NOT FOUND 2021/02/18 08:45:12 VOLUME BFL499 REQUEST REJECT - VOLUME NOT FOUND 2021/02/18 08:45:12 VOLUME BFL502 REQUEST REJECT - VOLUME NOT FOUND 2021/02/18 08:45:12 VOLUME BFL503 REQUEST REJECT - VOLUME NOT FOUND 2021/02/18 08:45:12 VOLUME BFL504 REQUEST REJECT - VOLUME NOT FOUND 2021/02/18 08:45:12 VOLUME BFL601 REQUEST REJECT - VOLUME NOT FOUND ...
Årsak
There are "B" prefixed tapes in both the legacy VTS and the DLm, so that when the DLMSCR job inputs the daily or full scratch report, it is receiving input for both DLm tapes and VTS tapes.
Oppløsning
The DLm should not share tape ranges with another tape system.
Pre-sort scratch list prior to DLMSCR run.
Berørte produkter
DD for DLm8100, Disk Library for mainframe DLm2100, Disk Library for mainframe DLm2500, Disk Library for mainframe DLm8100, Disk Library for mainframe DLm8500, Dell License Manager (DLM), VNX for DLm2100, VNX for DLm8100Produkter
DD for DLm6000, Disk Library for mainframe DLm2700, Disk Library for mainframe DLm8700, VNX for DLm2000, VNX for DLm6000Artikkelegenskaper