DLM: DLMSCR messages for volume not found

Sammendrag: DLMSCR is attempting to scratch tapes which reside only in a customer's legacy virtual tape system, not the DLm.

Denne artikkelen gjelder for Denne artikkelen gjelder ikke for Denne artikkelen er ikke knyttet til noe bestemt produkt. Det er ikke produktversjonene som identifiseres i denne artikkelen.

Symptomer

After a migration from another vendor Virtual Tape System to the DLm using third-party software, the DLMSCR job is running a long time and producing numerous 'volume not found' messages.
 

DLMSCR   VER 4.42     DLMCTRL = C5FF  PARM(TYPE=RMM,PREFIX=IB,PREFIXLN=1,DEV=C
2021/02/18 08:45:12 VOLUME  BFL111  REQUEST REJECT - VOLUME NOT FOUND         
2021/02/18 08:45:12 VOLUME  BFL499  REQUEST REJECT - VOLUME NOT FOUND         
2021/02/18 08:45:12 VOLUME  BFL502  REQUEST REJECT - VOLUME NOT FOUND         
2021/02/18 08:45:12 VOLUME  BFL503  REQUEST REJECT - VOLUME NOT FOUND         
2021/02/18 08:45:12 VOLUME  BFL504  REQUEST REJECT - VOLUME NOT FOUND         
2021/02/18 08:45:12 VOLUME  BFL601  REQUEST REJECT - VOLUME NOT FOUND   
...



 

 

Årsak

There are "B" prefixed tapes in both the legacy VTS and the DLm, so that when the DLMSCR job inputs the daily or full scratch report, it is receiving input for both DLm tapes and VTS tapes.  

 

Oppløsning

The DLm should not share tape ranges with another tape system. 

Pre-sort scratch list prior to DLMSCR run.

Berørte produkter

DD for DLm8100, Disk Library for mainframe DLm2100, Disk Library for mainframe DLm2500, Disk Library for mainframe DLm8100, Disk Library for mainframe DLm8500, Dell License Manager (DLM), VNX for DLm2100, VNX for DLm8100

Produkter

DD for DLm6000, Disk Library for mainframe DLm2700, Disk Library for mainframe DLm8700, VNX for DLm2000, VNX for DLm6000
Artikkelegenskaper
Artikkelnummer: 000186327
Artikkeltype: Solution
Sist endret: 23 mai 2025
Versjon:  5
Få svar på spørsmålene dine fra andre Dell-brukere
Støttetjenester
Sjekk om enheten din er dekket av støttetjenestene.