Connectrix MDS upgrade returns message "Pre-upgrade check failed "Return code -1."

Sammendrag: When performing Connectrix MDS upgrade, the "install all" command returns the message "Pre-upgrade check failed. "Return code -1."

Denne artikkelen gjelder for Denne artikkelen gjelder ikke for Denne artikkelen er ikke knyttet til noe bestemt produkt. Det er ikke produktversjonene som identifiseres i denne artikkelen.

Symptomer

On attempt to run "install all" command, the switch returns the message "Pre-upgrade check failed. "Return code -1."

No indications of what is wrong, md5sum of the firmware files are good. Enough space on the bootflash: and also on the standby supervisor but still the "install all" command fails with "Return code -1."

Årsak

The command
"show incompatibility-all system bootflash:m9700-sf2ek9-xxxx.bin"

 runs fine.

The command
 "show install all impact kickstart bootflash:m9700-sf2ek9-kickstart-mz.xxxx.bin system bootflash:m9700-sf2ek9-mz.xxxx.bin" fails with "Return code -1."

(This is the same message as the "install all" command.)

Oppløsning

Workaround:
  1. Perform a "system switchover" command to failover to the second supervisor. Wait until the command completes. Use the command "show system redundancy status" to confirm the action completes.
  2. Perform a second "system switchover" command to go back to the previously active supervisor where the upgrade code currently resides. 
  3. Rerun the "install all" command and upgrade should complete.

Berørte produkter

Connectrix MDS-9710-V2, Connectrix MDS-Series Firmware 8.X

Produkter

Connectrix MDS-9506, Connectrix MDS-9509, Connectrix MDS-9513, Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9718, Connectrix MDS-9718-V3
Artikkelegenskaper
Artikkelnummer: 000197811
Artikkeltype: Solution
Sist endret: 10 sep. 2025
Versjon:  6
Få svar på spørsmålene dine fra andre Dell-brukere
Støttetjenester
Sjekk om enheten din er dekket av støttetjenestene.