PowerStore: Clusters that have SAS Expansion Enclosures may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5
Sammendrag: Clusters that have one or more SAS Expansion Enclosures, may experience unexpected node reboots when running PowerStoreOS versions 3.0 to 3.5.
Denne artikkelen gjelder for
Denne artikkelen gjelder ikke for
Denne artikkelen er ikke knyttet til noe bestemt produkt.
Det er ikke produktversjonene som identifiseres i denne artikkelen.
Symptomer
The PowerStore nodes may unexpectedly reboot if these conditions are met:
- The cluster is on PowerStoreOS version 3.0.x, 3.2.x, or 3.5.x.
- There are one or more SAS expansion enclosures attached to any of the appliances in the cluster.
Årsak
The SAS drivers may time out due to a lock issue on the SAS controller.
This in turn causes a node unexpected reboot.
This in turn causes a node unexpected reboot.
Oppløsning
The issue is resolved in PowerStoreOS version 3.6 and above.
Berørte produkter
PowerStoreArtikkelegenskaper
Artikkelnummer: 000203131
Artikkeltype: Solution
Sist endret: 29 jul. 2025
Versjon: 24
Få svar på spørsmålene dine fra andre Dell-brukere
Støttetjenester
Sjekk om enheten din er dekket av støttetjenestene.