PowerProtect Cyber Recovery: Error - "The storage interface name provided for multilink object is not valid"
Sammendrag: Error when adding an interface to Multilink, stating that the object is invalid.
Denne artikkelen gjelder for
Denne artikkelen gjelder ikke for
Denne artikkelen er ikke knyttet til noe bestemt produkt.
Det er ikke produktversjonene som identifiseres i denne artikkelen.
Symptomer
Customer is getting this error when trying to configure multi link.
ERROR: Failed to modify application:<CyberSense Server hostname> The storage interface name vethx.xxx provided for multilink object with storage ID xxxxx is not valid.
Årsak
Issue is due to a limitation with the number of interfaces on the vault Data Domain being more than 20.
Oppløsning
DD ../network/interfaces REST API only returns 20 interfaces by default, this has been extended to 100 in CR Release 19.13.0.3.
Release Notes/Installation guide for multilink configuration prerequisites must be followed to avoid further issues.