PowerStore: System Check detects unnecessary de-stages

Podsumowanie: The System Check detects if there are unnecessary de-stages, which may lead to excessive drive wear.

Ten artykuł dotyczy Ten artykuł nie dotyczy Ten artykuł nie jest powiązany z żadnym konkretnym produktem. Nie wszystkie wersje produktu zostały zidentyfikowane w tym artykule.

Objawy

If the System Check detects the excessive wear issue, the following error message is displayed: "Possible issue causing excessive wear on drives is detected. (KB#000220203)"

Screenshot of the PowerStore Manager:image.png

When detected by the service script svc_health_check:
[...@ABCDEF-A ~]$ svc_health_check run -rhc dp_dedupe_destage_leak_check
Name                               Location  Status     Description
Datapath Dedup Destage Leak        node_a    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
Datapath Dedup Destage Leak        node_b    Failed     Possible issue causing excessive wear on drives is detected. (KB#000220203)
 
 
SUMMARY Status: Failed
   Passed:      0
   Failed:      2
   Total:       2
 

Przyczyna

The system check detects the issue of KB 000206257 PowerStore: NVMe SSD may wear faster due to increased write amplification.

The issue is resolved in 3.6 and later.

Rozwiązanie

If the issue is detected, upgrade to 3.6 or later.
If upgrade to 3.6 cannot be performed in the near future, contact technical support for assistance. Reference this KB Article for expedited handling. A script can be run to remedy the excessive drive wear from occurring in the future.

Dodatkowe informacje

Produkty, których dotyczy problem

PowerStore
Właściwości artykułu
Numer artykułu: 000220203
Typ artykułu: Solution
Ostatnia modyfikacja: 14 cze 2025
Wersja:  3
Znajdź odpowiedzi na swoje pytania u innych użytkowników produktów Dell
Usługi pomocy technicznej
Sprawdź, czy Twoje urządzenie jest objęte usługą pomocy technicznej.