DSA-2025-339: Security Update for Dell Avamar Data Store Gen5A Multiple Third-Party Component Vulnerabilities
Podsumowanie: Dell Avamar Data Store Gen5A remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.
Ten artykuł dotyczy
Ten artykuł nie dotyczy
Ten artykuł nie jest powiązany z żadnym konkretnym produktem.
Nie wszystkie wersje produktu zostały zidentyfikowane w tym artykule.
Skutki
Critical
Szczegóły
| Third-party Component | CVEs | More Information |
| Dell PowerEdge Server BIOS | CVE-2024-38796, CVE-2024-28956, CVE-2024-45332, CVE-2024-48012, CVE-2026-26945 | DSA-2025-038, DSA-2025-041, DSA-2025-156, DSA-2025-046, DSA-2026-113 |
| Integrated Dell Remote Access Controller (iDRAC) | CVE-2025-26466, CVE-2024-45490, CVE-2024-45491, CVE-2024-45492, CVE-2024-50602, CVE-2024-2961, CVE-2023-6780, CVE-2024-52533, CVE-2023-52340, CVE-2024-42154, CVE-2026-26948 | DSA-2025-145. DSA-2025-146, DSA-2024-460, DSA-2026-113 |
Produkty, których dotyczy problem, i środki zaradcze
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
| Avamar Data Store Gen5A | Dell PowerEdge Server BIOS | Versions prior to 2.24.0 | Version 2.24.0 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Avamar Data Store Gen5A | Integrated Dell Remote Access Controller (iDRAC) | Versions prior to 7.00.00.181 | Version 7.00.00.181 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Product | Software/Firmware | Affected Versions | Remediated Versions | Link |
| Avamar Data Store Gen5A | Dell PowerEdge Server BIOS | Versions prior to 2.24.0 | Version 2.24.0 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
| Avamar Data Store Gen5A | Integrated Dell Remote Access Controller (iDRAC) | Versions prior to 7.00.00.181 | Version 7.00.00.181 | Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901) |
Notes:
- This security includes both newly remedied and past vulnerabilities included in this cumulative update.
- Dell recommends upgrading to the latest release/version of your product. To schedule a platform security patch installation or firmware upgrade, please contact Dell Customer Support.
Known Issue:
- Upgrading directly to the August 2025 firmware, which includes BIOS 2.24.0, may fail on systems running BIOS versions prior to 2.12.2, due to compatibility constraints.
Required Action:
- To verify the BIOS version, run the following command in the Avamar console as an admin/root user:
omreport system version
- If the BIOS version is earlier than 2.12.2 contact Dell Customer Support to apply the September 2021 firmware block (AVP: Gen5aSep2021Blk338753.avp) before installing the August 2025 firmware.
Obejścia problemu i środki zaradcze
None
Historia zmian
| Revision | Date | Description |
| 1.0 | 2025-09-01 | Initial Release |
| 2.0 | 2025-10-06 | Replaced the NVD generic search link with the PowerEdge and iDrac advisories |
| 3.0 | 2025-10-22 | Major update to include CVE-2024-48012 |
| 4.0 | 2025-12-30 | Updated 'Additional Information' section |
| 5.0 | 2026-05-06 | Major update to include CVE-2026-26945 |
| 6.0 | 2026-05-07 | Major update to include CVE-2026-26948 |
Powiązane informacje
Zastrzeżenie prawne
Produkty, których dotyczy problem
Avamar, Avamar Data Store, Avamar Data Store Gen5A, Avamar ServerWłaściwości artykułu
Numer artykułu: 000362542
Typ artykułu: Dell Security Advisory
Ostatnia modyfikacja: 07 maj 2026
Znajdź odpowiedzi na swoje pytania u innych użytkowników produktów Dell
Usługi pomocy technicznej
Sprawdź, czy Twoje urządzenie jest objęte usługą pomocy technicznej.