DSA-2025-339: Security Update for Dell Avamar Data Store Gen5A Multiple Third-Party Component Vulnerabilities

Podsumowanie: Dell Avamar Data Store Gen5A remediation is available for multiple security vulnerabilities that could be exploited by malicious users to compromise the affected system.

Ten artykuł dotyczy Ten artykuł nie dotyczy Ten artykuł nie jest powiązany z żadnym konkretnym produktem. Nie wszystkie wersje produktu zostały zidentyfikowane w tym artykule.

Skutki

Critical

Szczegóły

Third-party Component CVEs More Information
Dell PowerEdge Server BIOS CVE-2024-38796, CVE-2024-28956, CVE-2024-45332, CVE-2024-48012, CVE-2026-26945  DSA-2025-038, DSA-2025-041, DSA-2025-156, DSA-2025-046, DSA-2026-113
Integrated Dell Remote Access Controller (iDRAC) CVE-2025-26466, CVE-2024-45490, CVE-2024-45491, CVE-2024-45492, CVE-2024-50602, CVE-2024-2961, CVE-2023-6780, CVE-2024-52533, CVE-2023-52340, CVE-2024-42154, CVE-2026-26948 DSA-2025-145. DSA-2025-146, DSA-2024-460, DSA-2026-113

Firma Dell Technologies zaleca wszystkim klientom uwzględnienie zarówno wyniku podstawowego CVSS, jak i wszelkich istotnych wyników czasowych i środowiskowych, które mogą mieć wpływ na potencjalną dotkliwość związaną z konkretną luką w zabezpieczeniach.

Produkty, których dotyczy problem, i środki zaradcze

Product Software/Firmware Affected Versions Remediated Versions Link
Avamar Data Store Gen5A Dell PowerEdge Server BIOS Versions prior to 2.24.0 Version 2.24.0 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)
Avamar Data Store Gen5A Integrated Dell Remote Access Controller (iDRAC) Versions prior to 7.00.00.181 Version 7.00.00.181 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)

 

Product Software/Firmware Affected Versions Remediated Versions Link
Avamar Data Store Gen5A Dell PowerEdge Server BIOS Versions prior to 2.24.0 Version 2.24.0 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)
Avamar Data Store Gen5A Integrated Dell Remote Access Controller (iDRAC) Versions prior to 7.00.00.181 Version 7.00.00.181 Avamar Data Store Gen5A Update for Server Nodes (Hotfix 338901)

 

Notes:

Known Issue:

  • Upgrading directly to the August 2025 firmware, which includes BIOS 2.24.0, may fail on systems running BIOS versions prior to 2.12.2, due to compatibility constraints.

  

Required Action:

  • To verify the BIOS version, run the following command in the Avamar console as an admin/root user:
     omreport system version
  • If the BIOS version is earlier than 2.12.2 contact Dell Customer Support to apply the September 2021 firmware block (AVP: Gen5aSep2021Blk338753.avp) before installing the August 2025 firmware.

Obejścia problemu i środki zaradcze

None

Historia zmian

RevisionDateDescription
1.02025-09-01Initial Release
2.02025-10-06Replaced the NVD generic search link with the PowerEdge and iDrac advisories
3.02025-10-22Major update to include CVE-2024-48012
4.02025-12-30Updated 'Additional Information' section
5.02026-05-06Major update to include CVE-2026-26945
6.02026-05-07Major update to include CVE-2026-26948 

Powiązane informacje

Produkty, których dotyczy problem

Avamar, Avamar Data Store, Avamar Data Store Gen5A, Avamar Server
Właściwości artykułu
Numer artykułu: 000362542
Typ artykułu: Dell Security Advisory
Ostatnia modyfikacja: 07 maj 2026
Znajdź odpowiedzi na swoje pytania u innych użytkowników produktów Dell
Usługi pomocy technicznej
Sprawdź, czy Twoje urządzenie jest objęte usługą pomocy technicznej.