Dell Unity: PUHC falhou para ERROR_CODE=platform::check_for_hardware_faults_2
Resumo: Falha na PUHC (Pre Upgrade Health Check, verificação de integridade pré-upgrade) do Dell Unity ERROR_CODE=platform::check_for_hardware_faults_2
Este artigo aplica-se a
Este artigo não se aplica a
Este artigo não está vinculado a nenhum produto específico.
Nem todas as versões do produto estão identificadas neste artigo.
Sintomas
Falha na PUHC do Dell Unity para ERROR_CODE = platform::check_for_hardware_faults_2
One or more errors have occurred. Follow the instructions provided to correct the problem and try again. Upgrade cannot proceed. -------------------------------------Errors------------------------------------- Platform: Check for hardware faults A power supply hardware fault (AC Power Loss) detected on: spb Action : Check you power cables. If correct, contact your online portal for replacement instructions. ERROR_CODE=platform::check_for_hardware_faults_2|Error|spb Platform: Check for enclosure faults A fault in the DPE enclosure was detected Action : Contact your online portal for corrective instructions. ERROR_CODE=platform::check_for_enclosure_faults_2|Error| --------------------------------------------------------------------------------
Causa
Como parte da verificação de integridade pré-upgrade, os estados de hardware dos seguintes componentes são examinados:
Fontes de alimentação
Unidades
de bateria reserva Ventiladores
DAE
do DPE
O erro platform::check_for_hardware_faults_2 indica que foi detectada uma falha no compartimento do DPE.
No exemplo acima, o problema específico é uma falha de hardware da fonte de alimentação (perda de energia CA) detectada em: spb
Fontes de alimentação
Unidades
de bateria reserva Ventiladores
DAE
do DPE
O erro platform::check_for_hardware_faults_2 indica que foi detectada uma falha no compartimento do DPE.
No exemplo acima, o problema específico é uma falha de hardware da fonte de alimentação (perda de energia CA) detectada em: spb
Resolução
Verifique os alertas da GUI e as coletas de dados de qualquer hardware com falha e substitua-os conforme necessário.
Neste exemplo, a fonte de alimentação B0 do DPE não está recebendo energia e está pronta para uma substituição.
TRiiAGE_full_SPlogs.txt
A 04/29/24 09:53:25.471 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:28.451 Bus0 Enc0 PowB 1678006 [ERROR] System: Power Supply is Faulted (GenFlt/AcFail ). B 04/29/24 09:53:28.458 espkg 1670066 [INFO] System: PS_MGMT CacheStatus changes from: OK to DEGRADED. B 04/29/24 09:53:48.597 DGSSP 1 [INFO] System: 04/29/2024 09:53:07 | BMC Power Supply Status | PS1_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 A 04/29/24 09:54:15.409 DGSSP 1 [INFO] System: 04/29/2024 09:53:06 | BMC Power Supply Status | PSB_Status | External Fault | Asserted ELOG(632) 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0xB800 0x7E : 0x00 0x80 : 0x08 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0800 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x8000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 0x79 : 0x0000 0x7E : 0x00 0x80 : 0x10 0x01 : 0x80 0x02 : 0x15 B 04/29/24 09:54:16.285 Health 601f4 [CRIT] User: Power supply DPE Power Supply B0 is not receiving power B 04/29/24 09:54:16.465 Health 60516 [ERROR] User: System dsus017d2-un32 has experienced one or more problems that have had a major impact.
SPB_fbecli_exe_ccollectall.txt
---------------------------------------------------------------- FBECLI> sptime: Current Time: 05/16/24 10:08:26.283 SP TimeStamp: 14267394886ms ---------------------------------------------------------------- FBECLI> spstat: SP B [Passive SP] PEER SP: PRESENT HW Cache Status: DEGRADED Reason: PS Physical memory: SPA(65536 MB), SPB(65536 MB) DPE-MIRANDA 0 (Bus 0, Pos 0) -OK EnclFaultLedStatus: ON EnclFaultLedReason: PS Fault PS A B OK (0214) FLT (0214)
Produtos afetados
Dell EMC Unity, Unity All Flash, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Family, Dell EMC Unity Hybrid, Unity Hybrid flash, Dell Unity Operating Environment (OE)Propriedades do artigo
Número do artigo: 000228125
Tipo de artigo: Solution
Último modificado: 29 jul. 2025
Versão: 4
Encontre as respostas de outros usuários da Dell para suas perguntas.
Serviços de suporte
Verifique se o dispositivo está coberto pelos serviços de suporte.