Compellent: Cross Platform Replication Storage Notification: Only One Path to Device Disk
Summary: Receiving alerts of "Only One Path to Device" for one or more disk indexes when using Cross Platform Replication.
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
When using Cross Platform Replication (SC array to PS array), there is the possibility of receiving alerts for having only one path to the device for one or multiple disk object indexes. Replication disk objects are created on the SC array for each cross-platform replication setup.
These alerts are viewable from Dell Storage Manager as follows:
In DSM Client > Storage Pane > Summary tab:

In DSM Client > Alerts tab:

Cause
If there is only a single port on each SC controller being used for this replication, then alerts are generated indicating there is only one path to device for each disk object. If there are two ports from each SC controller being used for replication, then the alerts are not generated.
Resolution
The feature is working as designed and these alerts can be ignored if it is by choice to only use one port from each SC controller for Cross Platform Replication. In order to stop these alerts, another port from each SC controller must be added to the replication Fault Domain.
Produse afectate
Entry Level & Midrange, Compellent (SC, SCv & FS Series), Legacy Storage ModelsProprietăți articol
Article Number: 000136589
Article Type: Solution
Ultima modificare: 21 Aug 2025
Version: 6
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.