Data Domain: Alert - IO module has failed | EVT-ENVIRONMENT-00029
Summary: When an I/O Module (aka SLIC or PCI card) fails or is removed from a Data Domain (DD), the system generates the Error: EVT-ENVIRONMENT-00029: Event Message: I/O module has failed.
Acest articol se aplică pentru
Acest articol nu se aplică pentru
Acest articol nu este legat de un produs specific.
Acest articol nu acoperă toate versiunile de produs existente.
Symptoms
The failure or removal of an I/O card (e.g SAS, NIC, NVRAM, FC) results in loss of communication to the affected card.
Hot-Swap of PCIe devices is NOT supported.
Note: Hot-swap triggers an unexpected reboot of the system.
Alert Example:
Alert Id: 147
Event Id: EVT-ENVIRONMENT-00029
Event Message: I/O module has failed
Object: Enclosure=1:Slot=7
Additional Information: Cause=A hardware fault occurred
This KB applies to PCIe devices; the same alert can also be generated against a Trusted Platform Module (TPM)
- For failed TPM - see KB: Data Domain: Alert: ENVIRONMENT-00029: TPM I/O Module Has Failed
Cause
The failure or removal of a system module (I/O card)
Resolution
Check and confirm the status of the affected card:
- DDCLI (SSH) # system show hardware
- A failed or removed card slot reported as '(empty)'
- Example:
sysadmin@DD# sys show hardware Slot Vendor Device Ports ---- ------ ------------------------------- -------------- M QLogic QL41000 4x 10GBase-T (NDC) Ma, Mb, Mc, Md 1 QLogic QL41164 4x 10GbE SFP+ 1a, 1b, 1c, 1d 2 EMC NVRAM 16GB Card 3 EMC PMC Quad Port 12 Gbps SAS 3a, 3b, 3c, 3d 4 Intel Intel QuickAssist Adapter 8970 5 EMC Quad Port 16 Gbps Fibre Channel 5a, 5b, 5c, 5d 6 QLogic QL41000 2x 25GbE 6a, 6b 7 (empty) (empty) 8 QLogic QL41000 2x 25GbE 8a, 8b ---- ------ ------------------------------- --------------- This example show slot 7 as (empty) as the card in that slot had failed.
-
- This output can be compared to Auto-Support to determine the missing card if all slots are not populated.
If the card was removed accidentally:
- Power off the DD unit, DDCLI (SSH):
-
# system poweroff
-
- Reinstall the card as needed
- Power the system back on.
If the card is suspected to be faulty or failed, contact your Support Provider to investigate and arrange a repair or replacement.
Produse afectate
Data Domain, Data Domain Deduplication Storage Systems, Integrated Data Protection Appliance Family, PowerProtect Data Protection HardwareProprietăți articol
Article Number: 000203868
Article Type: Solution
Ultima modificare: 16 Dec 2025
Version: 5
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență