Dell Unity: Neo14:60258 A Drive in the Unity Array has Failed and Requires Replacement

Summary: This article explains how to address or order a failed drive in a Dell Unity system for SymptomCode: Neo14:60258 (User Correctable)

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

This error message shows that there is a faulted disk in the Dell Unity system.

SymptomCode: neo14:60258 DAE x y Disk zz has failed

Or

SymptomCode: neo14:60258 DPE  Disk zz has failed

This drive must be replaced (Part Number xxxxxxxxx, Serial Number yyyyyyyy)"

 

Cause

The identified drive has faults and requires replacement.

 

Resolution

Proceed with the normal drive replacement process.

Log in to Unisphere to learn more about this alert. Click EVENTS > Alerts, and then select the alert to view the details.

Go to other related pages to further investigate the situation.

Obtain the following information about the drive (required):

  • Location:
  • Part Number:

Additional information can be helpful in confirming the correct replacement part is ordered. (Optional)

  • Raw Capacity:
  • Rotational Speeds:

 

Dell Storage Unity Family: Remove and Install 3.5" Disk Drive Replacement.

Duration: 00:02:36 (hh:mm:ss)
When available, closed caption (subtitles) language settings can be chosen using the CC icon on this video player.

CRU VIDEO AVAILABLE! Dell Technologies has produced a short video explaining and demonstrating this replacement process.
How to replace 3.5 Disk Drive for Unity Family

Additional Information

In addition, the following alerts may also be generated along with the drive failure alert (14:60258).

Please verify the part number of the failed drive and ensure it matches the part number in the alert.  If they match and a Service Request (SR) has been generated, the additional alert can be safely ignored.  Otherwise, please take any necessary action based on the alert message.

 

Message ID

Message

Alert Severity

Needs Action (Y/N)

14:60515

system degraded alert.

Warning

N

14:6032d

Storage pool degraded alert.

Warning

N

14:60343

Storage pool rebuilding due to the loss of a drive alert.

Warning

N

14:60346

Storage pool does not have enough spare space and becomes degraded.

Critical

Y

14:60342

The system could not start an automatic copy of data from one or more drives in pool, because spare drives are not available.

Critical

Y

14:60389

NAS server is not accessible and its services are not available.

Error

Y

14:6032b

Storage pool is offline.

Critical

Y

14:60514

System has experienced one or more problems that have had a critical impact.

Critical

N

14:6076f

Replication session encountered an error that halted its progress. 

Critical

Y

14:60345

Storage pool does not have enough spare space.

Warning

Y

14:6027c

Disk is reaching the end of its service life and needs to be replaced.

Warning

Y

14:60461

A system drive has failed on Storage Processor

Critical

Y

14:60651

The DPE has faulted because of a drive fault.

Error

Y

14:601a3

%2 has faulted because of a drive fault

Error

Y

14:602c4

LCC has a connection fault. It may have occurred because of a faulted drive, cable, or the LCC itself.

Error

Y

 

Produse afectate

Dell EMC Unity, Dell EMC Unity Family |Dell EMC Unity All Flash, Dell EMC Unity Family, Dell EMC Unity Hybrid
Proprietăți articol
Article Number: 000227400
Article Type: Solution
Ultima modificare: 26 May 2026
Version:  8
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.