PowerEdge: vSAN Ready Nodes unable to find vSAN network list during cluster turn on

Summary: During cluster turn on of vSAN ready nodes, the vSAN network list does not exist. This causes the virtual machine (VM) status to be invalid.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

The VM status as invalid As shown in the below screenshot

vmware

 

Cause

This issue is caused due to reboot_helper.py prepare script which is used during shutdown of the node.

This script prepares the node so that the cluster can be shut down. In addition, this script removes vSAN services from the VMkernel dedicated for vSAN.

networking

 
 

Resolution

To resolve the issue, enable the vSAN services on the VMkernel dedicated for vSAN.

The below command has to be run on all the vSAN cluster nodes.

command

 

 

Produse afectate

Dell EMC vSAN Ready Nodes, Dell EMC vSAN C6420 Ready Node, Dell EMC vSAN MX740c Ready Node, Dell EMC vSAN MX750c Ready Node, Dell vSAN Ready Node MX760c, Dell EMC vSAN R440 Ready Node, Dell EMC vSAN R640 Ready Node, Dell EMC vSAN R6415 Ready Node , Dell EMC vSAN R650 Ready Node, Dell EMC vSAN R6515 Ready Node, vSAN Ready Node R660, Dell vSAN R6615 Ready Node, Dell EMC vSAN R740 Ready Node, Dell EMC vSAN R740xd Ready Node, Dell EMC vSAN R750 Ready Node, Dell EMC vSAN R7515 Ready Node, Dell EMC vSAN R760 Ready Node, Dell vSAN R7615 Ready Node, Dell vSAN Ready Node R7625, Dell EMC vSAN R840 Ready Node, Dell EMC vSAN T350 Ready Node ...
Proprietăți articol
Article Number: 000297877
Article Type: Solution
Ultima modificare: 07 Nov 2025
Version:  2
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.