PowerStore Alerts: Interconnect Module Power Status
Summary: This article addresses the alert indicating that an interconnect module's power status is off.
Symptoms
When Dell PowerStore encounters an issue, an error alert is generated to help identify the issue. This article explains the different possible causes and the relevant solutions for these error alerts. If your problem is not resolved despite the solution that is provided, check the Dell Technical Support contact options.
Cause
Cause is mentioned in Resolution section under respective alerts.
Resolution
| Alert ID | XMS_CMI_FRU_POWER_STATUS_OFF |
| Alert Text | The power status of the interconnect module is off. |
| Error Code | 0x0030F203 |
| Impact | When an interconnect module powers off, the connection between two nodes within the appliance is lost. This prevents communication between nodes required for cluster coordination and data synchronization. The affected node may enter service mode to prevent data inconsistency, which can lead to service degradation. |
| Resolution | Cause:
The interconnect module power status may be off due to various hardware and environmental factors: Hardware failure: The interconnect module itself may have failed, preventing it from powering on or maintaining power. Connection problem: Poor or faulty connection between the interconnect module and the node can interrupt power delivery. Firmware or controller issue: A firmware malfunction or controller failure within the interconnect module or power management system may prevent proper power state. Administrative action: The interconnect module may have been intentionally powered off for maintenance, replacement, or troubleshooting purposes. Solution: To recover the power status of the interconnect module, perform the following steps in order: Reboot the node
Reseat the interconnect module
Replace the interconnect module
|