Troubleshooting Wyse 3040 Thin Client Power LED Amber Error Code

Summary: Resolve the Wyse 3040 Thin Client power LED amber error code caused by external pressure on the chassis. Discover how this triggers a CMOS reset and steps to recover your device.

Acest articol se aplică pentru Acest articol nu se aplică pentru Acest articol nu este legat de un produs specific. Acest articol nu acoperă toate versiunile de produs existente.

Symptoms

Affected Products:

  • Wyse 3040

Units experience a power LED display error code flash cycle of three amber LEDs, followed by one amber LED. LED error flash cycle repeats three times, followed by one long amber LED, and then continues to POST (turn on self-test).

Thin client display's the following error messages during POST:

Invalid configuration information - please run SETUP program.

Time-of-day not set - please run SETUP program.

Press F1 key to retry boot.
Press F2 key for setup utility.
Press F5 key to run onboard diagnostics.

POST Error message

Cause

A manufacturing design is the cause of the issue, where WIFI antenna wires are routed on top of the CLEAR CMOS button on the motherboard.

Resolution

To recover, press F1 to retry boot, and the error message goes away.

Produse afectate

Wyse 3040 Thin Client
Proprietăți articol
Article Number: 000126115
Article Type: Solution
Ultima modificare: 26 iul. 2024
Version:  9
Găsiți răspunsuri la întrebările dvs. de la alți utilizatori Dell
Servicii de asistență
Verificați dacă dispozitivul dvs. este acoperit de serviciile de asistență.