The FC Wan Com ports will be connected to dual separate backbone fabrics or networks that span two sites.
This allows for data flow between the two VPlex clusters in a Metro configuration without requiring a merged fabric between the two sites.

All A2-FC00 and B2-FC00 ports, or A2-XG00 and B2-XG00 ports, from both clusters will connect to one fabric or network and all A2-FC01 and B2-FC01 ports, or A2-XG01 and B2-XG01 ports, will connect to the other fabric or network.
This provides a redundant network capability where each director on one cluster communicates with all the directors on the other site even in the event of a fabric or network failure.

The zoning needs to be fixed such that:
  • all [A|B]2-FC00 only see (are zoned with) remote [A|B]2-FC00 ports 
  • all [A|B]2-FC01 only see (are zoned with) remote [A|B]2-FC01 ports 
  • all [A|B]2-FC02 only see (are zoned with) remote [A|B]2-FC02 ports 
  • all [A|B]2-FC03 only see (are zoned with) remote [A|B]2-FC03 ports 
Please refer to the "Implementation and Planning Best Practices for EMC VPLEX Technical Notes" for configuring FC WAN COM ports.
 
 
kA5j0000000TNVFCA4_1_0
 
On the first fabric
Zone 1:
              Cluster 1 : Dir A : Port A2-FC00
              Cluster 2 : Dir A : Port A2-FC00
Zone 2:
              Cluster 1 : Dir A : Port A2-FC00
              Cluster 2 : Dir B : Port B2-FC00
Zone 3:
              Cluster 1 : Dir B : Port B2-FC00
              Cluster 2 : Dir A : Port A2-FC00
Zone 4:
              Cluster 1 : Dir B : Port B2-FC00
              Cluster 2 : Dir B : Port B2-FC00
 
kA5j0000000TNVFCA4_1_1
 
On second fabric
Zone 1:
              Cluster 1 : Dir A : Port A2-FC01  
              Cluster 2 : Dir A : Port A2-FC01
Zone 2:
              Cluster 1 : Dir A : Port A2-FC01
              Cluster 2 : Dir B : Port B2-FC01
Zone 3:
              Cluster 1 : Dir B : Port B2-FC01
              Cluster 2 : Dir A : Port A2-FC01
Zone 4:
              Cluster 1 : Dir B : Port B2-FC01
              Cluster 2 : Dir B : Port B2-FC01