Unable to Register PowerMax Array, Error "400 Failed to discover VMAX system" in VSI plugin

Zhrnutie: Unable to register Storage Systems, receive message "No PowerMax/VMAS arrays visible" and while registering Storage System, "400 Failed to discover VMAX system, invalid connection. Status code: 400, Bad Request." ...

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Symptómy

The error 400 Failed to discover VMAX system, invalid connection. Status code: 400, Bad Request is displayed in STEP 2 of registering a storage system in the Virtual Storage Integrator (VSI) plugin:
 
Standalone Unisphere registration issue

In STEP 3, the message No Storage systems are available to Register in the VSI Plugin is received.
513-array-unable to register

Message seen in iapi-rest log:
Caused by: com.emc.iapi.core.exception.IapiException: Invalid port number '443' Status code: 400, Bad Request

com.emc.iapi.core.exception.IapiException: Failed to discover VMAX systems, invalid connection. Status code: 400, Bad Request

org.jooby.Err: (400): Bad Request

Caused by: com.emc.iapi.core.exception.IapiException: Failed to discover VMAX systems, invalid connection. Status code: 400, Bad Request

Message seen in iapi-rest-error log:
com.emc.iapi.core.exception.IapiException: Invalid port number '443' Status code: 400, Bad Request

org.jooby.Err: (400): Bad Request

Caused by: com.emc.iapi.core.exception.IapiException: Invalid port number '443' Status code: 400, Bad Request

2022-09-01 14:12:59 [utow task-2] ERROR c.e.p.a.v.c.u.UnisphereConnection:80 - The request to the server failed: com.emc.pie.commons.exception.ErrorStatusCodeException: The HTTP request to host [hostname] failed with status [400]: [connect timed out]

com.emc.iapi.core.exception.IapiException: Failed to discover VMAX systems, invalid connection. Status code: 400, Bad Request

org.jooby.Err: (400): Bad Request

Caused by: com.emc.iapi.core.exception.IapiException: Failed to discover VMAX systems, invalid connection. Status code: 400, Bad Request

Príčina

Connection requests to embed Unisphere are timed out.

Extensive uptime on the containers seems to prevent the discovery of arrays from the VSI plugin.

Slowness of the Unisphere for PowerMax UI was also observed.

Riešenie

Reboot the MGMT containers.

Once the containers are rebooted, the arrays are available to register in the VSI plugin.

Dotknuté produkty

Virtual Storage Integrator (VSI), Unisphere for PowerMax
Vlastnosti článku
Číslo článku: 000203472
Typ článku: Solution
Dátum poslednej úpravy: 29 jan 2025
Verzia:  4
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.