PowerFlex 3.X: Error Parsing CSV: The amount of NVDIMMM devices mismatches the amount of its acceleration pools

Zhrnutie: When uploading a PowerFlex CSV file with multiple NVDIMM Acceleration Devices assigned with the Acceleration pool defined once. You receive the following error. "Error Parsing CSV: The amount of NVDIMM devices mismatches the amount of its acceleration pools. Ensure the number of NVDIMM devices matches the number of its acceleration pools." ...

Tento článok sa vzťahuje na Tento článok sa nevzťahuje na Tento článok nie je viazaný na žiadny konkrétny produkt. V tomto článku nie sú uvedené všetky verzie produktov.

Pokyny

Scenario:  User configures CSV to deploy a PowerFlex cluster using the PowerFlex Gateway/Installer.

PowerFlex Gateway/Installer. 
User selects configured CSV and clicks "Upload installation CSV"

User receives the following error.

The amount of NVDIMMM devices mismatches the amount of its acceleration pools 

Reason for Error
The error points to a configuration issue with the configuration for the CSV "comma-separated value" configuration for the number of acceleration devices compared to the defined Acceleration Pool List. The CSV file had three Acceleration devices defined but only defined the Acceleration Pool once. For the configuration to validate. You need a 1 to 1 configuration definition for dax to acceleration pool.

Problem
Example configuration that would trigger this error.

NVDIMM Acceleration Device List
/dev/dax0.0,/dev/dax1.0,/dev/dax2.0

NVDIMM Acceleration Pool List
AccPoo101

 

Solution
Configuration that passes validation. 

NVDIMM Acceleration Device List
/dev/dax0.0,/dev/dax1.0,/dev/dax2.0

NVDIMM Acceleration Pool List
AccPoo101,AccPoo101,AccPoo101


Validation

image.png