PowerFlex: SO Node deployment fails as the OS repository is missing DellEMCPowerFlexEMbeddedOS2
Zhrnutie: Storage Only (SO) Node Deployment fails as the OS repository is missing on the MVMs after a resynchronization.
Tento článok sa vzťahuje na
Tento článok sa nevzťahuje na
Tento článok nie je viazaný na žiadny konkrétny produkt.
V tomto článku nie sú uvedené všetky verzie produktov.
Symptómy
SO node deployment fails after a resynchronization of the repository. New OS directories are created, and the expected OS directory is not available on the MVMs.
Príčina
-
DellEMC PowerFlex EMbeddedOS 3 (RHEL) and DellEMC PowerFlex EMbeddedOS 4 (SUSE) were created after a resync.

- PowerFlex Manager was trying to deploy using DellEMC PowerFlex EMbeddedOS 2 (SUSE)
-
In
/opt/platfrom/fileshare/[deploymentID]/on each MVM the DellEMCPowerFlexEMbeddedOS2 is no longer available.
Riešenie
Create the directory and copy the contents from the required repository and retry the deployment. As this was a SUSE deployment, The neeeded files are from DellEMCPowerFlexEMbeddedOS4.
Example:
cp -r DellEMCPowerFlexEMbeddedOS4 DellEMCPowerFlexEMbeddedOS2
Dotknuté produkty
PowerFlex rack, PowerFlex Appliance, PowerFlex custom node, PowerFlex custom nodeVlastnosti článku
Číslo článku: 000248816
Typ článku: Solution
Dátum poslednej úpravy: 03 jan 2026
Verzia: 3
Nájdite odpovede na svoje otázky od ostatných používateľov spoločnosti Dell
Služby podpory
Skontrolujte, či sa na vaše zariadenie vzťahujú služby podpory.