Pokyny

Before deploying PowerFlex Management Controller 2.0:
1. Configure port channel and trunk configuration data for network automation.

2. Install VMware ESXi on PowerFlex management controller.

3. Ensure that all management controller nodes are accessible.
Important: The deployment process is identical for both PowerFlex rack and PowerFlex appliance.
Configurations

Step of deploying the SVM OS

  1. Log in to VMware vCSA.
  2. Go to:
    Menu → Shortcuts → Hosts and Clusters, then expand the datacenter and cluster.
  3. Right-click the ESXi host → Select Deploy OVF Template.
  4. Choose Local file → Upload file → Browse to the SVM OVA template:
    • For PowerFlex Management Controller 2.0 cluster:
      ScaleIOVM_3nics_SLES_x.x.xxxx_xxx.ova
  5. Click Open → Next.
  6. Enter VM name:
    pfmc-<svm-ip-address>
     
    • For multi-VLAN setups, ensure correct IP per Logical Configuration Survey.
    • For multisubnet setups, a single port-group is created for the same VLAN ID.
  7. Click Next.
  8. Select the cluster and node for deployment. Verify no compatibility warnings → Next.
  9. Click Next again.
  10. Review details → Next.
  11. Select Local datastore, choose Thin Provision for virtual disk format.
  12. Under VM Storage Policy, check Disable Storage DRS for this VMNext.
  13. Select pfmc-sds-mgmt- for VM network → Next.
    (Ensure correct port-group for multi-VLAN setups.)
  14. Click Finish.

Adjust resources and network settings, then enable DirectPath IO.

  1. Edit VM Settings:
    • CPU: 12 CPUs, 12 cores per socket
    • Reservation: Enter GHz value → 17.4.
    • Memory: 18 GB, check Reserve all guest memory.
    • Network Adapters:
      • Adapter 1 → pfmc-sds-mgmt-<vlanid>
      • Adapter 2 → pfmc-sds-data1-<vlanid>
      • Adapter 3 → pfmc-sds-data2-<vlanid>
    • Remove two unused interfaces from OVA.
    • Add New Device → PCI Device → Enable DirectPath IO:
      • PCI Device = HBA 355i Front BroadCom / LSI
    • Click OK.

Component Installation
Install the following PowerFlex packages on all controller nodes in order:

  1. ActiveMQ - Message Broker Service
  2. Lightweight Installation Agent (LIA)
  3. Storage Data Server (SDS)
  4. 4. Meta Data Manager (MDM)

 

Certificate Generation
Generate temporary self-signed certificates required for PowerFlex cluster installation. These
Certificates will be replaced with production certificates post-deployment.

 

Cluster Deployment
Run the deployment script to create the PowerFlex cluster on the management controller. This
Process:
Configures the MDM cluster
Establishes communication between components
Initializes the storage infrastructure

 

Protection Domain Configuration
After cluster creation:
1. Add protection domains.
2. Create storage pools.
3. Provision volumes
4. Map volumes to datastores

 

Final Configuration Steps
Complete the management controller setup:
1. Create VMFS datastores.
2. Remove default vSwitch0.
3. Enable VMware High Availability (HA)
4. Enable VMware Distributed Resource Scheduler (DRS)

Dotknuté produkty