VxRail: RASR Process Fails With "Script 15_setup_node.sh execution error"

摘要: RASR process fails with "Installation Status: ERROR: Script 15_setup_node.sh execution error"

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

When attempting to reset DELL VxRail nodes using the RASR reset procedure, the RASR process may fail with the following error:
"Installation Status: ERROR: Script 15_setup_node.sh execution error"
Screenshot of RASR error 

There are two possible failure scenarios observed in the field:

1. The following messages can be seen in fist.log (VxRail: How to collect the logs to troubleshoot a RASR issue?)

"Failed to generate disk mappings, ERROR:('Invalid slot %s on disk %s', u'N/A', u'50000397bc896591')"


And

Got response from PTAgent. Code 200


2. During the RASR process, the following warnings were encountered while preparing the system:

Could not bring up network (Did not get an IP Address from DHCP server)


And the ipv4 address will always show 0.0.0.0 in DCUI. The following message is also shown in fist.log:

msg = '503 Service Unavailable (Failed to connect to endpoint: [N7Vmacore4Http16LocalServiceSpecE:0x03e100b8] _serverNamespace = /sdk action = Allow _port = 8307)' 

 

 

原因

Scenario#1: This issue can be caused if the vxadmin account is removed from the iDRAC users list.
To check if the vxadmin user is present, connect to the iDRAC UI and goto iDRAC Settings->User Authentication.

Scenario#2: This issue can be caused by improper network configuration from the switch side. 

解决方案

Scenario#1: If the vxadmin account is not present it must be added, see: VxRail: iDRAC settings that cannot be changed
Once the vxadmin has been added back with all appropriate permissions and password, reattempt the RASR procedure.

Scenario#2:  Disconnect the network cable from the switch and perform RASR again.

受影响的产品

VxRail, VxRail 460 and 470 Nodes, VxRail Appliance Series, VxRail G Series Nodes, VxRail D Series Nodes, VxRail D560, VxRail D560F, VxRail E Series Nodes, VxRail E460, VxRail E560, VxRail E560F, VxRail E560N, VxRail E660, VxRail E660F, VxRail E660N , VxRail E665, VxRail E665F, VxRail E665N, VxRail G560, VxRail G560F, VxRail P Series Nodes, VxRail P470, VxRail P570, VxRail P570F, VxRail P580N, VxRail P670F, VxRail P670N, VxRail P675F, VxRail P675N, VxRail S Series Nodes, VxRail S470, VxRail S570, VxRail S670, VxRail Software, VxRail V Series Nodes, VxRail V470, VxRail V570, VxRail V570F, VXRAIL V670F, VxRail VD-4510C, VxRail VD-4520C, VxRail VD Series Nodes, VxRail VE-660, VxRail VE-6615, VxRail VP-760, VxRail VP-7625, VxRail VS-760 ...
文章属性
文章编号: 000050335
文章类型: Solution
上次修改时间: 17 6月 2025
版本:  4
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。