[Isilon] Node fails to boot or reimage to OneFS v8.1.x after Back-End Conversion

摘要: Customer wanted to convert the IB back-end network to ETH. The conversion procedure only exists on v8.2 code. After the conversion, the customer wanted to revert the new nodes back to v8.1 so a USB re-image took place. The re-image process failed. ...

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状



After an IB-to-ETH back-end network conversion procedure (an internal DELL EMC PS service), the attempted re-image of a node to v8.1.x failed with the following error:

Verifying hardware configuration...
No backend network devices detected for LNI.xml creation. Actual NIC type: 40 GigE, Expected: Infiniband
Verify Hardware exited with an error.
Aborting boot.

原因

Nodes that were built with backend IB interfaces contain a special type of backend NIC called a VPI card. This NIC is capable of both InfiniBand and Ethernet networking. The backend conversion process introduced in OneFS 8.2 allows the card to be switched from IB mode to Ethernet mode, enabling cluster migration to an Ethernet backend network. Prior versions of OneFS do not 'understand' that this card can operate in either mode, and when this card is detected in those versions it is presumed to be an InfiniBand card, causing the hardware check to fail since the configured backend type (Ethernet) does not match the detected backend type ('InfiniBand').

解决方案

Nodes with VPI backend NICs operating in Ethernet mode are only supported in OneFS v8.2 and newer, and cannot be downgraded to an older version. Once OneFS 8.2 or newer is reinstalled, the node will function normally.

受影响的产品

Isilon

产品

Isilon, Isilon A200, Isilon F800, Isilon Gen6, Isilon H400, Isilon H500, Isilon H5600, Isilon H600, PowerScale OneFS
文章属性
文章编号: 000173413
文章类型: Solution
上次修改时间: 10 9月 2025
版本:  4
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。