Connectrix MDS upgrade returns message "Pre-upgrade check failed "Return code -1."
摘要: When performing Connectrix MDS upgrade, the "install all" command returns the message "Pre-upgrade check failed. "Return code -1."
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
On attempt to run "install all" command, the switch returns the message "Pre-upgrade check failed. "Return code -1."
No indications of what is wrong, md5sum of the firmware files are good. Enough space on the bootflash: and also on the standby supervisor but still the "install all" command fails with "Return code -1."
No indications of what is wrong, md5sum of the firmware files are good. Enough space on the bootflash: and also on the standby supervisor but still the "install all" command fails with "Return code -1."
原因
The command
runs fine.
The command
(This is the same message as the "install all" command.)
"show incompatibility-all system bootflash:m9700-sf2ek9-xxxx.bin"
runs fine.
The command
"show install all impact kickstart bootflash:m9700-sf2ek9-kickstart-mz.xxxx.bin system bootflash:m9700-sf2ek9-mz.xxxx.bin" fails with "Return code -1."
(This is the same message as the "install all" command.)
解决方案
Workaround:
- Perform a "system switchover" command to failover to the second supervisor. Wait until the command completes. Use the command "show system redundancy status" to confirm the action completes.
- Perform a second "system switchover" command to go back to the previously active supervisor where the upgrade code currently resides.
- Rerun the "install all" command and upgrade should complete.
受影响的产品
Connectrix MDS-9710-V2, Connectrix MDS-Series Firmware 8.X产品
Connectrix MDS-9506, Connectrix MDS-9509, Connectrix MDS-9513, Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9718, Connectrix MDS-9718-V3文章属性
文章编号: 000197811
文章类型: Solution
上次修改时间: 10 9月 2025
版本: 6
从其他戴尔用户那里查找问题的答案
支持服务