PowerStore: Metro devices report target port group with zero target port count on Linux hosts

摘要: Target Port Group (TPG) values and information are incorrect on PowerStore Metro volumes on a Linux system for PowerStoreOS versions 3.x.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

Target Port Group (TPG) values and information are incorrect on PowerStore Metro volumes on a Linux system for PS-OS versions 3.x.
 

 

原因

The nonauthoritative TPG information (essentially the remote TPG data), for the PowerStore Metro ports are not reported correctly from PowerStore.
ESXi always accepts the authoritative information about a path, i.e. the information that comes back on path1 about path1 is authoritative. Arrays are also required to report information about paths they do not own. These are called nonauthoritative paths. PowerStore remote nonauthoritative paths return incorrect information about the TPGs.

 

 

解决方案

Metro protection in PowerStoreOS versions 3.x supports FC/SCSI or iSCSI connected VMware ESXi hosts.

For more information, see "Dell EMC PowerStore Release Notes" and "Dell EMC PowerStore Protecting Your Data" documents for appropriate version. 

 

受影响的产品

PowerStore