Validating Physical NICs are Symmetric Fails When Creating Network ATC NetIntent When Using Intel X710 Network Adapters
摘要: During the Network ATC NetIntent validation process for Intel X710 Network Adapters, an error arises due to inconsistencies identified within the NICs' description.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
说明
Example of the difference in network adapter descriptions which causes the validation error.
Figure 1: Example of the different Intel NIC network adapter descriptions
Figure 2: Example two of the different Intel NIC network adapter descriptions
Example of different driver versions on network adapters which causes the difference in network adapter descriptions.
Figure 3: Example of Intel Drivers versions on the network adapters which cause the issue
Resolution:
The recommendation is to install Intel NIC Family version 21.5.0 drivers which are designed for Microsoft Azure Stack, version 22H2, with package ID NVPY7. You can access the driver package using the provided link.
Known Issues::
After Downgrade the Driver may still show 1.16.208 even though the installer says it is .206. If so you must either uninstall the driver or re-upgrade to .208 and then attempt to downgrade again.
Figure 1: Example of the different Intel NIC network adapter descriptions
Figure 2: Example two of the different Intel NIC network adapter descriptions
Example of different driver versions on network adapters which causes the difference in network adapter descriptions.
Figure 3: Example of Intel Drivers versions on the network adapters which cause the issue
Resolution:
The recommendation is to install Intel NIC Family version 21.5.0 drivers which are designed for Microsoft Azure Stack, version 22H2, with package ID NVPY7. You can access the driver package using the provided link.
- Driver download: Enter the link attached to this article to access the driver download required to address this issue.
- Driver information: Intel NIC Family Version 21.5.0 Drivers for Microsoft Azure Stack, Version 22H2
Known Issues::
After Downgrade the Driver may still show 1.16.208 even though the installer says it is .206. If so you must either uninstall the driver or re-upgrade to .208 and then attempt to downgrade again.
受影响的产品
Dell EMC Microsoft Storage Spaces Direct Ready Nodes, Storage Spaces Direct R440 Ready Node, Storage Spaces Direct R640 Ready Node, Storage Spaces Direct R740xd Ready Node, Storage Spaces Direct R740xd2 Ready node附件