Dell Networking OS6 N series switches getting logs ERR truncating integer value > 32 bits

摘要: This article explains about log message ERR truncating integer value > 32 bits in Dell Networking OS6.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

A message will be registered on the log as shown below filling switch buffer logs

General[procLOG]: l7_ns_mibs.c(XXXX) XXXXXXXX %% ERR truncating integer value > 32 bits

The impact will be the following one:

  • There is no functional impact on the switch 
  • Wrong uptime is seen while polling for switch uptime.
  • Log messages as shown below fills buffer logs
Sample log message
 
Mar 22 21:39:51 General[procLOG]: l7_ns_mibs.c(XXXX) XXXXXXXX %% ERR truncating integer value > 32 bits

原因

  • If the switches uptime is more than 497 days, this message would be output when snmp polling is done to bellow MIB or OID
SNMP MIB : agentInventoryUnitUpTime
SNMP OID : 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.13.2.2.1.14
  • The reason for this log message is because MIB agentInventoryUnitUpTime is Counter32, which means it is a 32-bit integer counter. If 497 days of switch uptime is crossed, then its corresponding integer value exceeds 32 bit and hence value overflows.

解决方案

It's advised to take the following actions mentioned below.

    1. From 6.8.1.1 this log message level is DEBUG instead of ERROR. Hence it can be upgrades to any firmware to 6.8.1.1 and above.

     2.Stop polling to   
SNMP MIB : agentInventoryUnitUpTime
SNMP OID : 1.3.6.1.4.1.674.10895.5000.2.6132.1.1.13.2.2.1.14
                                                                                      
     3. Restart the switch so that the uptime value resets.