摘要: During a OneFS upgrade, a Gen 5 Isilon node (S210/X210/X410/NL410/HD400) reports an upgrade failure with the error Boot device mirrors are not valid in the isi_upgrade_logs.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
While upgrading OneFS on a cluster, one of the nodes reports an upgrade failure. Running isi_upgrade_logs on the cluster displays a message similar to:
# isi_upgrade_logs 1 2023-11-20T21:57:10 /usr/sbin/isi_upgrade_agent_d Warn AgentFork:error 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform Verifying boot device mirrors are synced... 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform Traceback (most recent call last): 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform File "/usr/sbin/isi_Upgrade_Agent.py", line 687, in <module> 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform if __name__ == "__main__": main(sys.argv) 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform File "/usr/sbin/isi_Upgrade_Agent.py", line 245, in main 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform e = engine.Engine() 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform File "/usr/local/lib/python2.7/site-packages/isi/sys/update/engine.py", line 119, in __init__ 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform File "/usr/local/lib/python2.7/site-packages/isi/sys/update/engine.py", line 159, in _device_init 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform File "/usr/local/lib/python2.7/site-packages/isi/sys/bootdisk.py", line 626, in init_providers 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform File "/usr/local/lib/python2.7/site-packages/isi/sys/bootdisk.py", line 2411, in verify_mirrors 1 2023-11-20T21:57:10 isi_Upgrade_Agent.py Inform isi.sys.bootdisk.BootdiskMirrorException: Boot device mirrors are not valid, missing components: var1
原因
There was a problem with one of the mirror objects on the internal boot drive for the node.
解决方案
Contact customer service and quote this article.
受影响的产品
Isilon HD400, Isilon NL410, Isilon S210, Isilon X210, Isilon X410文章属性
文章编号: 000219816
文章类型: Solution
上次修改时间: 05 12月 2023
版本: 1
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。