Connectrix: Brocade Syslogadmin and auditcfg commands return errors when viewing settings or making changes
摘要: Syslogadmin and auditcfg commands returning errors when attempting to view settings or make changes.
本文适用于
本文不适用于
本文并非针对某种特定的产品。
本文并非包含所有产品版本。
症状
The following errors are returned while running syslogadmin and auditcfg commands:
syslogadmin --show -ip Unable to retrieve information syslogadmin --set -ip 10.0.0.1 Unable to process this operation. auditcfg --show -filter Unable to retrieve audit configuration :-5
原因
During a supportsave, one or more modules may time out due to network issues or high CPU usage on the switch. This causes a communication issue between daemons, resulting in the reported errors.
解决方案
Work Around:
Perform a hareboot on a non-director or hafailover on a director during a scheduled maintenance window to clear the condition and allow the commands to complete.
Resolution:
Upgrade to FOS 9.2.0b where the defect is fixed.
受影响的产品
Connectrix B-Series文章属性
文章编号: 000226917
文章类型: Solution
上次修改时间: 04 6月 2025
版本: 2
从其他戴尔用户那里查找问题的答案
支持服务
检查您的设备是否在支持服务涵盖的范围内。