Connectrix: Brocade Syslogadmin and auditcfg commands return errors when viewing settings or making changes

摘要: Syslogadmin and auditcfg commands returning errors when attempting to view settings or make changes.

本文适用于 本文不适用于 本文并非针对某种特定的产品。 本文并非包含所有产品版本。

症状

The following errors are returned while running syslogadmin and auditcfg commands:

syslogadmin --show -ip
Unable to retrieve information

syslogadmin --set -ip 10.0.0.1
Unable to process this operation.

auditcfg --show -filter
Unable to retrieve audit configuration :-5

 

原因

During a supportsave, one or more modules may time out due to network issues or high CPU usage on the switch. This causes a communication issue between daemons, resulting in the reported errors.

 

解决方案

Work Around:
Perform a hareboot on a non-director or hafailover on a director during a scheduled maintenance window to clear the condition and allow the commands to complete.

 

Resolution:
Upgrade to FOS 9.2.0b where the defect is fixed.

 

受影响的产品