Connectrix MDS upgrade returns message "Pre-upgrade check failed "Return code -1."

摘要: When performing Connectrix MDS upgrade, the "install all" command returns the message "Pre-upgrade check failed. "Return code -1."

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

On attempt to run "install all" command, the switch returns the message "Pre-upgrade check failed. "Return code -1."

No indications of what is wrong, md5sum of the firmware files are good. Enough space on the bootflash: and also on the standby supervisor but still the "install all" command fails with "Return code -1."

原因

The command
"show incompatibility-all system bootflash:m9700-sf2ek9-xxxx.bin"

 runs fine.

The command
 "show install all impact kickstart bootflash:m9700-sf2ek9-kickstart-mz.xxxx.bin system bootflash:m9700-sf2ek9-mz.xxxx.bin" fails with "Return code -1."

(This is the same message as the "install all" command.)

解析度

Workaround:
  1. Perform a "system switchover" command to failover to the second supervisor. Wait until the command completes. Use the command "show system redundancy status" to confirm the action completes.
  2. Perform a second "system switchover" command to go back to the previously active supervisor where the upgrade code currently resides. 
  3. Rerun the "install all" command and upgrade should complete.

受影響的產品

Connectrix MDS-9710-V2, Connectrix MDS-Series Firmware 8.X

產品

Connectrix MDS-9506, Connectrix MDS-9509, Connectrix MDS-9513, Connectrix MDS-9706, Connectrix MDS-9706-V2, Connectrix MDS-9710, Connectrix MDS-9718, Connectrix MDS-9718-V3
文章屬性
文章編號: 000197811
文章類型: Solution
上次修改時間: 10 9月 2025
版本:  6
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。