PowerStore: Node reboot due to rasdaemon memory leak (OOM)
摘要: A PowerStore node may reboot due to a memory leak caused by an internal process (rasdaemon).
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
Symptoms may include:
This issue only affects PowerStore appliances running releases older than PowerStoreOS 3.2.
- A single node reboot (the node automatically recovers after the reboot).
- In rare cases, both nodes may be affected by this issue simultaneously, resulting in a short service disruption.
This issue only affects PowerStore appliances running releases older than PowerStoreOS 3.2.
原因
PowerStoreOS includes a process called rasdaemon which is responsible for monitoring and reporting various CPU errors to the upper layers. The rasdaemon utility comes bundled with the PowerStoreOS. An issue has been identified that may cause a memory leak when an underlying hardware issue exists. These underlying hardware issues are typically correctable errors on DIMMs and CPU. Every time an issue is encountered the process may leak memory until no memory is left.
解析度
This issue is fixed in PowerStoreOS 3.2.0 and later.
To determine if this issue has occurred, contact Dell Technical Support or your authorized service provider and reference this article.受影響的產品
PowerStore, PowerStoreOS文章屬性
文章編號: 000207130
文章類型: Solution
上次修改時間: 15 11月 2024
版本: 6