ECS: Fabric alerts not reported in ECS UI
摘要: Object-related alerts are received in the UI but not fabric-related alerts. Example of object alert that was received. Fabric-related alerts are missing which is the issue. Some of these alerts that would generate dial homes are also not being generated which means no fabric dial homes are generated. RAP180 - Issue with fabric alert sequence detected ...
本文章適用於
本文章不適用於
本文無關於任何特定產品。
本文未識別所有產品版本。
症狀
There is a lack of events or errors in the UI. On the below example the last UI alerts was on 2024-01-04 (current date 2024-01-17):
Running the below command shows that there are no fabric events. Only object type alerts in the last 14 days:
Command:svc_rest_cmd /vdc/alerts/
xDoctor shows below ERROR:RAP180 - Issue with fabric alert sequence detected
原因
This issue is linked to a Service Console (SC) issue which resets the fabric sequence when run on SC 8.2.0.0 or 8.2.0.1. This then causes UI fabric-related alerts to stop being reported.
解析度
Reach out to ECS Technical Support and note this knowledge article for a solution to be implemented.
受影響的產品
ECS Appliance Software with Encryption, ECS Appliance Software without Encryption, Elastic Cloud Storage文章屬性
文章編號: 000214964
文章類型: Solution
上次修改時間: 18 11月 2025
版本: 7