PowerStore: I/O error observed on NVMe datastore during NDU

摘要: ESXi host running 8.0 U1 using NVMe/FC and NVMe/TCP datastore may experience I/O errors during PowerStore node reboots/failures.

本文章適用於 本文章不適用於 本文無關於任何特定產品。 本文未識別所有產品版本。

症狀

Symptoms:
  • Hosts connected using NVMe/FC or NVMe/TCP may experience I/O errors during node reboots or NDU.

Environment:
  • ESXi Host 8.0 U1 is connected to PowerStore volumes/vVols. 
  • Host is connected using NVMe/FC or NVMe/TCP.

原因

This is a VMware regression issue introduced in ESXI version 8. 0 U1. In this release, ESXi introduced a Native NVMe stack (aka E2E NVMe stack). Certain error codes that had a retry in previous versions of ESXI no longer have a retry applied. As a result the end applications may experience I/O failures.

解析度

Upgrade ESXI to version 8.0 U1c or later.

其他資訊

受影響的產品

PowerStore
文章屬性
文章編號: 000216664
文章類型: Solution
上次修改時間: 14 6月 2025
版本:  4
向其他 Dell 使用者尋求您問題的答案
支援服務
檢查您的裝置是否在支援服務的涵蓋範圍內。