Gå til hovedindhold
  • Afgiv ordrer hurtigt og nemt
  • Se ordrer og spor status for din forsendelse
  • Opret og få adgang til en liste med dine produkter
  • Administrer dine Dell EMC-websteder, -produkter og -kontaktpersoner på produktniveau ved hjælp af Company Administration (Virksomhedsadministration).

Chassis Management Controller Version 2.0 for Dell PowerEdge VRTX User's Guide

Adding CMC User Using RACADM

To add a new user to the CMC configuration:
  1. Set the user name.
  2. Set the password.
  3. Set the user privileges. For information about user privileges, see Types of Users .
  4. Enable the user.
Example:
The following example describes how to add a new user named "John" with a "123456" password and login privileges to the CMC.
  • NOTE: For a list of valid bit mask values for specific user privileges, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide . The default privilege value is 0, which indicates that the privileges of a user are not enabled.
racadm config -g cfgUserAdmin -o cfgUserAdminUserName
                                    -i 2
                                    john
                                    racadm config -g cfgUserAdmin -o cfgUserAdminPassword
                                    -i 2
                                    123456
                                    racadm config -g cfgUserAdmin -i 2 -o
                                    cfgUserAdminPrivilege
                                    0x00000001
                                    racadm config -g cfgUserAdmin -i 2 -o
                                    cfgUserAdminEnable 1
                                 
To verify that the user was successfully added with the correct privileges, run the following command:
racadm getconfig –g cfgUserAdmin –i 2

For more information about the RACADM commands, see the Chassis Management Controller for PowerEdge VRTX RACADM Command Line Reference Guide available at dell.com/support/manuals.