Description
|
Displays information
related to iDRAC, managed system, and watchdog configuration.
-
NOTE: The host name and OS
Name fields in the
getsysinfo output display accurate
information only if the
Dell OpenManage Server Administrator is installed on the managed system. Else, these fields may be blank
or inaccurate. An exception to this are VMware operating system names,
which are displayed even if the
Server Administrator is not
installed on the managed system.
|
Synopsis
|
racadm getsysinfo [-d] [-s] [-w] [-A] [-c] [-4] [-6]
|
Input
|
-
—4 — Displays IPv4 settings
-
—6 — Displays IPv6 settings
-
—c — Displays common settings
-
—d —
Displays iDRAC information
-
—s — Displays system information
-
—w — Displays watchdog information
-
—A — Eliminates the printing of headers/labels
|
Output
racadm getsysinfo
RAC Information:
RAC Date/Time = Tue May 14 14:04:59 2013
Firmware Version = 1.40.40
Firmware Build = 13
Last Firmware Update = 05/10/2013 20:56:10
Hardware Version = 0.01
MAC Address = 90:B1:1C:11:3C:B7
Common settings:
Register DNS RAC Name = 0
DNS RAC Name = idrac-H1VGF2S
Current DNS Domain =
Domain Name from DHCP = Disabled
IPv4 settings:
Enabled = 1
Current IP Address = 192.168.0.1
Current IP Gateway = 192.168.0.1
Current IP Netmask = 192.168.0.1
DHCP Enabled = 1
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = Disabled
IPv6 settings:
Enabled = 0
Current IP Address 1 = ::
Current IP Gateway = ::
Autoconfig = 1
Link Local IP Address = ::
Current IP Address 2 = ::
Current IP Address 3 = ::
Current IP Address 4 = ::
Current IP Address 5 = ::
Current IP Address 6 = ::
Current IP Address 7 = ::
Current IP Address 8 = ::
Current IP Address 9 = ::
Current IP Address 10 = ::
Current IP Address 11 = ::
Current IP Address 12 = ::
Current IP Address 13 = ::
Current IP Address 14 = ::
Current IP Address 15 = ::
DNS Servers from DHCPv6 = Disabled
Current DNS Server 1 = ::
Current DNS Server 2 = ::
System Information:
System Model = PowerEdge R520
System Revision = I
System BIOS Version = 1.5.0
Service Tag = H1VGF2S
Express Svc Code = 37118600020
Host Name =
OS Name =
OS Version =
Power Status = ON
Fresh Air Capable = Yes
Watchdog Information:
Recovery Action = None
Present countdown value = 15 seconds
Initial countdown value = 15 seconds
Embedded NIC MAC Addresses:
NIC.Embedded.1-1-1 Ethernet = 90:B1:1C:11:3C:B5
WWN = 90:B1:1C:11:3C:B5
NIC.Embedded.2-1-1 Ethernet = 90:B1:1C:11:3C:B6
WWN = 90:B1:1C:11:3C:B6
Example
-
Display Chassis Information
racadm getsysinfo -c
-
Display CMC Information
racadm getsysinfo -d
-
racadm getsysinfo -A -s
""System
Information:" "PowerEdge R520" "I" "1.5.0" "H1VGF2S" "37118600020"
"" "" "" "ON" "Fresh Air Capable:" "Yes" "Embedded NIC MAC Addresses:"
"90:B1:1C:11:3C:B5" "90:B1:1C:11:3C:B5" "90:B1:1C:11:3C:B6" "90:B1:1C:11:3C:B6"
-
racadm getsysinfo -w -s
System Information:
System Model = PowerEdge R520
System Revision = I
System BIOS Version = 1.5.0
Service Tag = H1VGF2S
Express Svc Code = 37118600020
Host Name =
OS Name =
OS Version =
Power Status = ON
Fresh Air Capable = Yes
Watchdog Information:
Recovery Action = None
Present countdown value = 15 seconds
Initial countdown value = 15 seconds
Embedded NIC MAC Addresses:
NIC.Embedded.1-1-1 Ethernet = 90:B1:1C:11:3C:B5
WWN = 90:B1:1C:11:3C:B5
NIC.Embedded.2-1-1 Ethernet = 90:B1:1C:11:3C:B6
WWN = 90:B1:1C:11:3C:B6