Dell PowerEdge RAID Controller 11 User’s Guide PERC H755, H750, H355, and H350 Controller Series

Configured slot behavior

This feature is similar to persistent hot spare slot behavior. If a redundant VD is configured to the system and if a drive is replaced, the configured slot will automatically rebuild or copyback on the inserted drive regardless of the data on the drive. This operation will overwrite the data on the drive.

Table 1. Drive state/operationThis table shows the drive state operation.
Drive state/operation Unconfigured slot Slot configured in VD
Insert unconfigured drive into the system Ready Rebuild or copyback start
Insert configured drive into the system Foreign
  • Rebuild or copyback start
  • Original drive data lost
Insert configured locked drive into the system (unlockable) Foreign Cryptographic Erase (If configured VD is not secured)
  • Rebuild or copyback start
  • Original drive data lost
Insert locked drive into the system (non-unlockable) Foreign locked Foreign locked