Dell PowerEdge FN I/O Module Configuration Guide 9.10(0.0)

PDF

Disabling and Re-Enabling BFD

BFD is enabled on all interfaces by default, though sessions are not created unless explicitly configured.

If you disable BFD, all of the sessions on that interface are placed in an Administratively Down state ( the first message example), and the remote systems are notified of the session state change (the second message example).

To disable and re-enable BFD on an interface, use the following commands.

  • Disable BFD on an interface. INTERFACE mode no bfd enable
  • Enable BFD on an interface. INTERFACE mode bfd enable
If you disable BFD on a local interface, this message displays:
     R1(conf-if-gi-4/24)#01:00:52: %RPM0-P:RP2 %BFDMGR-1-BFD_STATE_CHANGE: Changed session state to 
                                 Ad
                                 Dn for neighbor 2.2.2.2 on interface Gi 4/24 (diag: 0)
                              
If the remote system state changes due to the local state administration being down, this message displays:
     R2>01:32:53: %RPM0-P:RP2 %BFDMGR-1-BFD_STATE_CHANGE: Changed session state to 
                                    Down for neighbor
                                    2.2.2.1 on interface Gi 2/1 (diag: 7)
                                 

Califique este contenido

Preciso
Útil
Fácil de comprender
¿Este artículo fue útil?
0/3000 characters
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Proporcione calificaciones (1 a 5 estrellas).
  Seleccione si el artículo fue útil o no.
  Los comentarios no pueden contener estos caracteres especiales: <>"(", ")", "\"