Power | ||
---|---|---|
AC Power Supply | ||
Wattage | 290 W | |
Heat dissipation | ||
Voltage | 100–240 V AC, autoranging, 50/60 Hz | |
Battery | ||
Coin-cell battery | 3 V CR2032 Lithium coin cell |
Drives | |||
---|---|---|---|
Hard drives | Up to four 3.5 inch and two 2.5 inch internal, cabled SATA hard drives | ||
Expansion Bus | |||
---|---|---|---|
Bus type | PCI Express Generation 3 | ||
Expansion card slots: | Supports three PCIe expansion card slots and one PCI expansion card slot |
Physical | |||
---|---|---|---|
Height | 36.29 cm (14.29 inch) with feet | ||
36.0 cm (14.17 inch) without feet | |||
Width | 17.5 cm (6.88 inch) | ||
Depth | 43.5 cm (17.12 inch) with bezel | ||
40.0 cm (15.75 inch) without bezel | |||
Maximum configuration weight | 8.6 kg (18.95 lb) | ||
Empty weight | 8 kg (17.64 lb) |
Environmental | ||
---|---|---|
Temperature | ||
Operating | Continuous operation: 10 °C to 35 °C at 10% to 80% relative humidity (RH), with 26 °C maximum dew point. De-rate maximum allowable dry bulb temperature at 1 °C/300 m above 900 m (1°F per 550 ft). | |
Storage | –40 °C to 65 °C (–40 °F to 149 °F) with a maximum temperature gradation of 20 °C per hour | |
Relative humidity | ||
Operating | 20% to 80% (noncondensing) at a maximum wet bulb temperature of 29 °C (84.2 °F) | |
Storage | 5% to 95% at a maximum wet bulb temperature of 38 °C (100.4 °F) | |
Maximum vibration | ||
Operating | 0.26 G rms at 5 Hz to 350 Hz (all operation orientations) | |
Non-operating | 2.2 G rms at 5 Hz to 500 Hz for 15 min (all six sides tested) | |
Maximum shock | ||
Operating | One shock pulse (all operating orientations) of 40 G for 2 ms in the operational orientation | |
Non-operating | Six consecutively executed
shock pulses in the positive and negative x, y, and z axes (one pulse
on each side of the system) of 71 G/2 ms half sine shock
Six consecutively executed shock pulses in the positive and negative x, y, and z axes (one pulse on each side of the system) of 50 G/320 inps long duration half sine shock |
|
Altitude | ||
Operating | –15.2 m to 3048 m (–50 to 10,000 ft) | |
Storage | –15.2 m to 10,668 m (–50 ft to 35,000 ft) | |
Airborne Contaminant Level | ||
Class | G1 as defined by ISA-S71.04-1985 |