메인 콘텐츠로 이동
  • 빠르고 간편하게 주문
  • 주문 보기 및 배송 상태 추적
  • 제품 목록을 생성 및 액세스

Integrated Dell Remote Access Controller 7 (iDRAC7) Version 1.50.50 User's Guide

Enabling Serial Connection IPMI Mode Using RACADM

To configure the IPMI mode, disable the RAC serial interface and then enable the IPMI mode using any of the following:
  • Using config command:
    racadm config -g cfgSerial -o cfgSerialConsoleEnable 0
    racadm config -g cfgIpmiSerial -o cfgIpmiSerialConnectionMode 
                                           < 0 
                                            or  1
                                           >
                                        

    where, 0 indicates Terminal mode and 1 indicates Basic mode.

  • Using set command:
    racadm set iDRAC.Serial.Enable 0
    racadm set iDRAC.IPMISerial.ConnectionMode 
                                           < 0 
                                            or  1
                                           >
                                        

    where, 0 indicates Terminal mode and 1 indicates Basic mode.