The following table describes the prerequisites for the FCoE solution
offered using M1000e (with MXL and FC FlexIOM), Brocade, and Dell
Compellent.
Table 1. Prerequisites for M1000e (with MXL and FC FlexIOM), Brocade,
and Dell Compellent
Resource |
Prerequisites |
MXL |
-
DCB needs to be enabled.
-
VLT needs to be disabled.
-
FC feature needs to be enabled on
the MXL. Remove “fip-snooping” feature if enabled on the MXL.
conf
feature fc
-
Port-channel member interfaces needs
to have following configuration.
interface range tengigabitethernet 0/33 – 36
port-channel-protocol lacp
port-channel 128 mode active
exit
protocol lldp
no advertise dcbx-tlv ets-reco
dcbx port-role auto-upstream
no shut
exit
-
Server facing ports needs to have
following configuration.
portmode hybrid
switchport
protocol lldp
dcbx port-role auto-downstream
no shut
exit
|
Brocade |
- Alias needs to be created having Compellent fault
domain WWPN accessible on Brocade switch. Create a single alias including
the virtual ports for the Compellent fault domain WWPN accessible
on Brocade switch. ASM automates the creation of each additional zone
for the server objects and place them into a zone config.
- Brocade root password needs to be changed so that
the banner presented to change the default password does not impact
ASM's ability to
ssh into the switch.
|
Dell Compellent |
Create fault domain as per Dell
Compellent best practices.
|