The following table describes the prerequisites for the FCoE solution offered using Rack Server, S5000, and Compellent. For more information, see http://en.community.dell.com/techcenter/extras/m/white_papers/20387203

Table 1. Prerequisites for Rack Server, S5000, and Compellent
Resource Prerequisites
S5000
  • DCB needs to be enabled.

  • VLT needs to be disabled.

  • Enable Fibre Channel capability and Full Fabric mode.

    • NOTE: All switches must have SSH connectivity enabled.
    feature fc 
                                                          fc switch-mode fabric-services
                                                          
                                                       
  • Enable FC ports connecting to Compellent storage array and FC ports connecting to other S5000 switch via ISL links.

    interface range fi 0/0 - 7 
                                                          no shut
                                                          
                                                       
  • Create DCB Map.

    dcb-map SAN_DCB_MAP
                                                          priority-group 0 bandwidth 60 pfc off 
                                                          priority-group 1 bandwidth 40 pfc on 
                                                          priority-pgid 0 0 0 1 0 0 0 0 
                                                          exit
                                                          
                                                       
  • Create a FCoE VLAN.

    interface vlan <VLAN ID> [Create VLAN for FCoE]
                                                          exit
                                                       
  • Create FCoE Map.

    fcoe-map default_full_fabric
                                                          fabric-id <FCoE VLAN ID> vlan <FCoE VLAN Id>
                                                          fc-map <FC MAP>
                                                          exit
                                                       
Compellent

Fault domain need to be created as per Compellent best practices.