iDRAC Quick Sync 2 module (optional) is on the front panel of your system.
Table 1. iDRAC Quick Sync 2 indicators and descriptionsThis table describes the Quick Sync status indicators. The indicator statuses are Off, which is the default state, Solid white, blinks white rapidly, blinks white slowly, blinks white five times rapidly, and then turns off, solid amber, and blinking amber.
iDRAC Quick Sync 2 indicator code
Condition
Corrective action
Off (default state)
Indicates that the iDRAC Quick Sync 2 feature is turned off. Press the iDRAC Quick Sync 2 button to turn on the iDRAC Quick Sync 2 feature.
If the LED fails to turn on, reset the left control panel flex cable and check. If the problem persists, see the
Getting help section.
Solid white
Indicates that iDRAC Quick Sync 2 is ready to communicate. Press the iDRAC Quick Sync 2 button to turn off.
If the LED fails to turn off, restart the system. If the problem persists, see the
Getting help section.
Blinks white rapidly
Indicates data transfer activity.
NA
If the problem persists, see the
Getting help section.
Blinks white slowly
Indicates that firmware update is in progress.
NA
If the indicator continues to blink indefinitely, see the
Getting help section.
Blinks white five times rapidly and then turns off
Indicates that the iDRAC Quick Sync 2 feature is disabled.
Check if iDRAC Quick Sync 2 feature is configured to be disabled by iDRAC.
If the problem persists, see the
Getting help section.