During the power counter roll-over for utilization, the power counter rolls over before the rollover counter. This leads to an erroneous power spike which may throttle the server.
Ενημερωμένοι: May 21, 2026
ID: 000225350
This is a firmware catalog which contains validated and certified firmware stack for selected Dell VMware vSAN Ready Nodes based on Dell customized ESXi 6.x branch-based Dell customized images.
Ενημερωμένοι: May 21, 2026
ID: 000225252
Initiating a graceful restart or shutdown using Redfish APIs may fail for the Windows Server Operating System.
Ενημερωμένοι: May 21, 2026
ID: 000224986
When Dell Intel E810-CQDA2 part number 85F8F or DWNRF is used with FR1 transceiver part number PJ62G, it cannot link up. The maximum power consumption of the transceiver Dell Part Number (DPN) PJ62G is 4W, which exceeds the NIC device's power supply limit of 3.5W.
Ενημερωμένοι: May 21, 2026
ID: 000224793
Dell solid state drive (SSD) fails after system reports low environment operating temperature.
Ενημερωμένοι: May 20, 2026
ID: 000224458
This article provides information about PERC ECC messages that are seen due to firmware memory handling issues.
Ενημερωμένοι: May 20, 2026
ID: 000223832
PERC H750, H755, and H755N controllers may experience single or multi-bit ECC messages.
Ενημερωμένοι: May 20, 2026
ID: 000223831
Microsoft Hyper-V Virtual Machine (VM) Live Migration may fail or no LUNs are mapped after powering on VMs due to Windows architecture and hardware configuration limiting the number of vFC LUNs.
Ενημερωμένοι: May 20, 2026
ID: 000223671
Failed to power on VMware virtual machine (VM) on R7525 with NVIDIA A40/L40 GPUs and 2.14.1 BIOS
Ενημερωμένοι: May 20, 2026
ID: 000223583
PowerEdge customers using Broadcom NXE adapters in VMware ESXi may experience unexpected results when attempting to tune port parameters. Particularly in configurations with multiple NXE adapters present, understanding the port ordering from both a VMware (vmnicX) and serverPCI-e Slot-Bus-Device-Function (SBDF) may be helpful to select the appropriate commands.
Ενημερωμένοι: May 20, 2026
ID: 000223479
Dell PowerEdge server with a Broadcom BCM57414 PCIe adapter could encounter intermittent network-disconnected problem in a VMware NSX-T environment.
Ενημερωμένοι: May 20, 2026
ID: 000223469
Dell Intel E810-C adapters do not support disabling the Virtual Machine Device Queue (VMDQ) loopback feature using "Intnetcli" tool.
Ενημερωμένοι: May 20, 2026
ID: 000223462
PowerEdge server intermittently encounters a UEFI iSCSI Boot From SAN (BFS) fatal error 8 upon booting with the PowerStore appliance.
Ενημερωμένοι: May 20, 2026
ID: 000223454
VMware vCenter registration may fail in OMEVV 1.3 with a custom certificate chain installed in OpenManage Enterprise (OME) or vCenter.
Ενημερωμένοι: May 20, 2026
ID: 000223404
Slow insertion of a SAS or SATA drive in PowerEdge 15G or 16G Servers with a PERC or HBA controller configuration causes a "No Access" bit to be set, leading to an inability to blink and unblink drives.
Ενημερωμένοι: May 20, 2026
ID: 000222941
On an ESXi host, if the Flow Control setting on the BCM5720 is modified without a cable inserted, the network interface card (NIC) may fail to establish a link when a cable is later inserted. The issue does not occur if the setting is modified with a cable inserted in the NIC port.
Ενημερωμένοι: May 20, 2026
ID: 000222793
Dell Samsung Serial Attached SCSI (SAS) PM1653 and PM1655 solid state drives may report excessive Sense Key faults 0x3, 0x11, 0x0, or 0x4, 0x29, 0x4. These faults have the potential to cause unexpected drive issues.
Ενημερωμένοι: May 20, 2026
ID: 000222201
When installing or restarting the ISM 5.1.1 on an ESXi 8.x environment, the VMK interface for BMC_Network vSwitch gets configured with a DHCP assigned address instead of static.
Ενημερωμένοι: May 20, 2026
ID: 000221985
Dell Enterprise SAS, SATA SSD: SMART predictive failures triggered by remaining write endurance falling below the threshold
Ενημερωμένοι: May 19, 2026
ID: 000221846
This article explains why the Windows Boot Drive (hosting the C:\ volume) may show as removeable media in Windows and how to override the behavior when necessary.
Ενημερωμένοι: May 19, 2026
ID: 000221557
In some migration scenarios, the OpenManage Enterprise 4.0 target import operation may fail with an error 'Failed to decrypt backup archive' during migration. Use the following article to help in troubleshooting this scenario and various ways to address the failure.
Ενημερωμένοι: May 19, 2026
ID: 000221490
The link speed of a NVIDIA ConnectX-7 Single Port NDR200 may show as Single Data Rate (SDR) in the IDRAC.
Ενημερωμένοι: May 19, 2026
ID: 000221452
Network port enumeration on Windows Server 2022 with Dell network adapters may swap port designations.
Ενημερωμένοι: May 19, 2026
ID: 000221408
An error occurs when attempting to apply default settings to a Dell Intel E810-2C Ethernet Adapter. These adapters are configured with Permit Total Port Shutdown enabled. Both ports have Port Option set to 4x25.
Ενημερωμένοι: May 19, 2026
ID: 000221407
When in a SNAPI enabled configuration, the Dell Mellanox Ethernet and InfiniBand NICs may display 0000:0000:0000:0000 as the virtual node GUID for the second partition.
Ενημερωμένοι: May 19, 2026
ID: 000221406
Firmware upgrades to Broadcom network devices may fail with a "libpci.so: Cannot open" error when run from a Smart Bootable ISO image created with Dell Repository Manager 3.x.
Ενημερωμένοι: May 19, 2026
ID: 000221180
This article provides three methods to confirm the SSD Piece Part Identification (PPID)
Ενημερωμένοι: May 19, 2026
ID: 000466928
After an update to 7.00.00.00 or higher, the iDRAC9 web server may become inaccessible where the user has uploaded a custom or CA signed web certificate.
Ενημερωμένοι: May 19, 2026