Skip to main content
PowerEdge R730xd image

PowerEdge R730xd

PowerEdge R730xd

Articles

Invalid entry. Please use only Letters, numbers and any special characters except <>)(%/;,=#-/*

30 out of 346 shown
346 out of 346 shown

This article shows how to add additional disks to a virtual disk or reconfigure a virtual disk.
Updated:  June 02, 2026 ID: 000116592

This article explains how to create and import an iDRAC certificate.
Updated:  May 28, 2026 ID: 000120158

Dell PowerEdge servers with common design components are grouped into generations, for example PowerEdge 17th generation servers, 16th generation, 15th generation, or 14th generation. This article provides general guidance for PowerEdge server model naming convention to identify the generation and common components. This article also lists all PowerEdge servers by model including type, CPU, generation, and remote management components.
Updated:  June 03, 2026 ID: 000137343

This article explains what disk errors PDR1001 and PDR3 mean on Dell PowerEdge servers and the best practices to resolve these issues. By understanding these alerts and acting promptly, you can maintain storage health, prevent downtime, and protect critical data.
Updated:  June 02, 2026 ID: 000143247

How to Identify the physical slot number in iDRAC based off the device name in vSphere/VSAN.
Updated:  June 01, 2026 ID: 000179543

This article provides information about exporting the Tech Support Report (TSR) / SupportAssist Collection, including the Operating System, Application Data, and the RAID controller log. This is done using the integrated Dell Remote Access Controller (iDRAC) command-line interface (CLI) of Dell PowerEdge servers generations 12, 13, and 14.
Updated:  June 01, 2026 ID: 000120100

This document answers questions about SupportAssist Enterprise.
Updated:  June 01, 2026 ID: 000060848

The drive will assert due to a log full condition after the first power cycle when it reaches 70000 Power On Hours (POH). The drive will not process read or write commands once in this state.
Updated:  May 25, 2026 ID: 000217034

This article provides steps to troubleshoot a chassis intrusion, chassis open message for PowerEdge servers.
Updated:  May 25, 2026 ID: 000136481

PowerEdge connected Dell NVMe SSDs with the Limited Retry (LR) bit set may experience an increase in failures due to elevated media and data‑integrity error rates.
Updated:  May 24, 2026 ID: 000415896

PowerEdge 14G, 15G, 16G, and 17G servers skip Preboot eXecution Environment (PXE) boot when an "Unavailable" entry is last in the boot order.
Updated:  May 24, 2026 ID: 000396285

Fans reporting FAN0000/FAN0001 errors (RPM below warning or critical) should be removed and swapped to another connector; if the error follows the fan, replace it.
Updated:  May 24, 2026 ID: 000391086

Dell PowerEdge Toshiba MG08 and MG09 hard drives may encounter uninterruptible Background Media Scanning (BMS), causing I/O errors, or timeouts.
Updated:  May 24, 2026 ID: 000381662

Encountering PR8 errors in the LifeCycle (LC) log when using a BlueField-3 (BF3) Data Processing Units (DPU) card (DPN: HFWRM).
Updated:  May 24, 2026 ID: 000379421

The article provides the solution to the firmware update errors for ConnectX-4 LX NICs SWB 76DNG version 14.32.21.02 & ConnectX-5 dual port SWB 1GF8G version 16.35.40.30.
Updated:  May 24, 2026 ID: 000378312

This article provides information about the LIC008 error seen when importing the IDRAC License.
Updated:  May 23, 2026 ID: 000353269

This article provides information about how to verify if a Network Interface Card (NIC) is compatible with a PowerEdge Server.
Updated:  May 23, 2026 ID: 000349619

This article provides information about CPU Machine Check errors and common causes and proper handling when errors are seen.
Updated:  May 23, 2026 ID: 000349127

Dell Samsung PM893 SSDs with Firmware HJ55 or Earlier Experience Premature SMART Failures
Updated:  May 23, 2026 ID: 000333265

R7725, R6725, R7715, and R6715 the number of CPU Cores is not recognized correctly.
Updated:  May 23, 2026 ID: 000321587

PowerEdge: Dell service support for end of industry production of 2.5" 15k RPM SAS hard drives
Updated:  May 23, 2026 ID: 000314166

PowerEdge servers crash with PCIe fatal errors while updating Kioxia CM6 NVMe drive firmware.
Updated:  May 22, 2026 ID: 000256907

Dust or chemical contamination at the endface of a fiber optic LC connector or transceiver module impedes signaling. Dell engineering teams have verified cases in which a fully functional port appears to be a bad port because dirty optical connectors manifest as a port failing loop testing with acceptable power measurement levels. Cable connectors should be cleaned and when stored must be protected from dust particle or chemical contamination.
Updated:  May 22, 2026 ID: 000246018

The Dell SS540 SAS solid state drive is reported as not correctly functioning.
Updated:  May 21, 2026 ID: 000237298

In Windows Server 2025, when leveraging CPUs with more than 256 cores, the Broadcom BCM5720 fails to retrieve a DHCP address, leading to no network connectivity.
Updated:  May 21, 2026 ID: 000233949

The article describes how to troubleshoot network connectivity issues for network cards.
Updated:  May 21, 2026 ID: 000227983

Seagate Skybolt and SkyboltServoBP drive fails with medium format corrupted errors.
Updated:  May 21, 2026 ID: 000227930

This article presents opportunities to understand and troubleshoot some common causes of fan noise in a PowerEdge server. It is also relevant for 100% fan speeds.
Updated:  May 21, 2026 ID: 000227912

This article provides information about Fatal BUS errors seen with PCI1360 and PCI1318.
Updated:  May 21, 2026 ID: 000227163

How to create Cluster Shared Volumes by manually calculating the necessary disk space value.
Updated:  May 21, 2026 ID: 000227068